基于多源数据的变压器的智能故障诊断和运行状态监控,基于融合和采矿数据
Jingping Cui1, Wei Kuang2, Kai Geng3
1Ural International Institute of Rail Transit, Shandong Polytechnic, Jinan, 250104, China. cjp_sdp_edu@163.com.
Scientific reports
|March 4, 2025
概括
本研究介绍了使用多源数据融合和相关性分析的智能变压器故障诊断系统. 该模型准确地预测变压器的健康状况,并警告潜在的故障,确保电力系统的可靠性.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 在工程领域的人工智能.
背景情况:
- 变压器的可靠性对于高效的电力系统运行至关重要.
- 预测和健康管理 (PHM) 对变压器至关重要.
- 现有的故障诊断方法需要对复杂数据进行增强.
研究的目的:
- 为变压器提出一种新的智能故障诊断方法.
- 整合多源数据以提高诊断准确度.
- 为了实现早期预警,并防止灾难性的故障.
主要方法:
- 多源数据融合使用改进的权方法.
- 混合深度学习模型:双向LSTM,注意力机制,CNN.
- 状态评估的先验相关性分析.
主要成果:
- 准确预测负载率,温度和溶解气体指数.
- 在采样点88处识别异常条件 (如电弧放电).
- 实现了0.917的平均故障诊断率,平均平方误差为0.018.
结论:
- 拟议的模型有效地诊断变压器故障,并预测早期警告.
- 多源数据融合和混合深度学习提高了诊断性能.
- 该系统有助于电力系统的安全可靠运行.
更多相关视频
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
5.8K
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
119
相关概念视频
Power System Three-Phase Short Circuits
71
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
71
Transformers in Distribution System
98
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
98
Differential Relays
94
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
94
Instrument Transformers
64
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
64
Energy Losses in Transformers
819
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
819
Reclosers and Fuses
78
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
78