相关实验视频
Updated: May 24, 2025

19:44
A Tactile Automated Passive-Finger Stimulator TAPS
Published on: June 3, 2009
13.6K
一个采集动脉脉冲信号的腕表,具有灵活的触觉传感密集阵列
概括
这项研究介绍了一款用于自动采集动脉脉冲信号的新型腕表. 它以8个维度捕获了全面的心血管数据,使先进的门诊监测成为可能.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 心血管监测 心血管监测
背景情况:
- 动脉脉冲信号为心血管健康提供了丰富的见解.
- 现有的可穿戴技术在全面的脉冲波分析方面存在局限性.
- 准确,多维的脉冲数据对于早期疾病检测至关重要.
研究的目的:
- 开发一种可穿戴系统,用于自动,高分辨率的动脉脉冲信号采集.
- 为了能够同时进行辐射动脉脉冲的多维 (8D) 测量.
- 创建一个紧的,低功耗的设备,用于门诊心血管监测.
主要方法:
- 在腕表中集成29x3的超小压力传感芯片密集阵列.
- 开发一个二维灵活的触觉传感系统,用于高分辨率的感知.
- 在时间和横截面领域同时记录脉冲波.
主要成果:
- 手表成功地获得了高分辨率的动脉脉冲信号.
- 该系统测量了辐射动脉脉冲的8个维度:深度,强度,速率,均性,流动性,宽度,刚度和稳定性.
- 这代表了第一个可穿戴系统,可以同时捕捉时间和截面的脉冲波数据.
结论:
- 开发的腕表提供了全面的,多维的动脉脉冲数据.
- 这项技术对于加强门诊心血管监测具有显著的潜力.
- 医生可以更好地获得详细的脉冲信号信息,以便更好地诊断.
相关概念视频
Pulse
412
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
412
Pulse Assessment Sites
884
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
884
Assessment of radial pulse
780
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
780
Equipments Used To Measure Blood Pressure
786
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
786
Special considerations while measuring pulse
551
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
551
Assessment of blood pressure in brachial artery(one-step method)
550
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
550