通过极化散射增强全内部反射显微镜的分辨率
Chenguang Liu1,2, Zhao Chen1, Zhenlong Xu1
1Advanced Microscopy and Instrumentation Research Center, School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin, China.
Journal of microscopy
|March 5, 2025
概括
这项研究引入了一种新的方法,通过使用 evanescent 波分析定向散射来提高无标签显微镜分辨率. 该技术提高了图像清晰度,并减少了文物,以便更好地进行长期的非侵入性观察.
科学领域:
- 显微镜的使用方法
- 光学物理学的光学物理学
- 生物技术是生物技术.
背景情况:
- 无标签显微镜对于非侵入性生物样本观察至关重要.
- 总内部反射显微镜 (TIRM) 提供高灵敏度,但面临着分辨率限制.
- 图像工件和激光斑点可以扭曲TIRM数据.
研究的目的:
- 开发一种新的方法来提高无标签全内反射显微镜的分辨率.
- 克服传统TIRM固有的分辨率限制.
- 为了减少显微镜成像中的图像扭曲和工件.
主要方法:
- 利用样本极性散射的方向差异.
- 在多向 evanescent 波的照明下捕捉微观图像.
- 计算各种角度获得的图像的高阶自相关积累.
主要成果:
- 在图像分辨率上实现了1.5倍的改进.
- 成功地减少了由激光斑点引起的扭曲.
- 有效地减轻图像工件,从而获得更清晰的数据.
结论:
- 开发的技术显著提高了无标签TIRM的分辨率.
- 这种方法可以为生物研究提供更清晰,更少文物成像.
- 它对先进的长期,非侵入性显微镜观测具有前景.
相关概念视频
Total Internal Reflection Fluorescence Microscopy
5.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.6K
Super-resolution Fluorescence Microscopy
6.8K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.8K
Imaging Biological Samples with Optical Microscopy
4.6K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
4.6K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
264
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
264
Phase Contrast and Differential Interference Contrast Microscopy
7.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
7.4K