非酶电化学传感器用于临床检测:当前状态,挑战和未来前景

Christoph Bruckschlegel1, Vivien Fleischmann1, Nenad Gajovic-Eichelmann2

  • 1Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstrasse 31, 93053, Regensburg, Germany.

Talanta
|March 6, 2025
PubMed
概括

非酶电化学传感器为基于酶的传感器提供了一个强大的,经济高效的替代品,用于点诊所 (POC) 测试. 本综述探讨了它们的发展,挑战以及在诊断和监测中广泛采用的未来方向.

相关概念视频

Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
1.0K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.5K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
2.3K
Amperometry: Overview01:10

Amperometry: Overview

Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
2.2K
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
88