使用多模式时间序列和集体变压器网络电机的故障诊断
Bo Xu1, Huipeng Li2,3, Ruchun Ding1
1School of Physics and Electronic Information, Huanggang Normal University, Huanggang, 438000, China.
Scientific reports
|March 6, 2025
概括
本研究介绍了一种先进的方法,用于使用多式联机数据融合和变压器网络来诊断感应电机故障. 该方法实现了高诊断精度,提高了工业设备的可靠性并降低了维护成本.
科学领域:
- 电气工程 电气工程
- 人工智能的人工智能
- 机械工程 机械工程
背景情况:
- 感应电机对于工业运行至关重要,需要有效的故障诊断来防止停机时间和优化维护.
- 当前的诊断方法经常与各种故障类型和复杂的操作环境作斗争.
- 尽量减少停机时间和维护成本对于工业生产的经济效率至关重要.
研究的目的:
- 为各种感应电机故障开发一种新的,高度准确的诊断方法.
- 整合多模式数据和先进的深度学习技术,以加强故障识别.
- 通过精确的故障诊断,提高工业设备的可靠性和效率.
主要方法:
- 收集的多模式数据包括三相电流,振动,设备声音和环境声音.
- 开发了一个集体变压器网络,利用自注意机制来实现动态功能集成.
- 采用混乱的鱼优化算法 (WOA) 来实现网络的超参数优化.
主要成果:
- 拟议的方法在一组多模式的电机测量数据集上实现了99.10%的诊断精度.
- 与单模数据分析和现有最先进的方法相比,表现出卓越的性能.
- 验证了多模数据融合和变压器网络在电机故障诊断中的有效性.
结论:
- 这种新的诊断方法为感应电机故障识别提供了出色的性能和可靠性.
- 多模式数据融合显著提高了诊断准确性,解决了单一来源数据的局限性.
- 该方法为确保连续工业生产和优化维护策略提供了强大的解决方案.
相关概念视频
Power System Three-Phase Short Circuits
71
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
71
Three-Phase Short Circuit—Unloaded Synchronous Machine
110
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
110
Three-Winding Transformers
182
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
182
Transformers with Off-Nominal Turns Ratios
129
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
129
Multimachine Stability
129
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
129
Energy Losses in Transformers
818
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
818