Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

198
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
198
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

164
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
164
Computed Tomography01:10

Computed Tomography

4.2K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.2K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

65
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
65
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

78
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
78
Positron Emission Tomography01:29

Positron Emission Tomography

4.0K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.0K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Corrigendum to 'Surveillance With Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography of Patients With Stage I-to-III Lung Cancer After Completion of Curative treatment (SUPE_R): A Randomized Controlled Trial' [Journal of Thoracic Oncology Volume 20 Issue 8 (2025) 1086-1097].

Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer·2026
Same author

Diagnostic Accuracy of [<sup>18</sup>F]FDG PET/CT versus CT for NSCLC Surveillance: Secondary Analysis of a Randomized Clinical Trial.

Clinical lung cancer·2025
Same author

Reliability of [<sup>18</sup>F]FDG PET/CT for post-treatment surveillance of non-small cell lung cancer: agreement among multiple centers.

European journal of nuclear medicine and molecular imaging·2025
Same author

Discrepancies in regional lung cancer multidisciplinary team decisions can be reduced through national consensus meetings.

Acta oncologica (Stockholm, Sweden)·2025
Same author

Surveillance With Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography of Patients With Stage I-to-III Lung Cancer After Completion of Curative treatment (SUPE_R): A Randomized Controlled Trial.

Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer·2025
Same author

ctDNA can detect minimal residual disease in curative treated non-small cell lung cancer patients using a tumor agnostic approach.

Lung cancer (Amsterdam, Netherlands)·2025

相关实验视频

Updated: May 23, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
09:55

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules

Published on: October 4, 2024

290

优化CT成像参数:核医学诊断准确性的影响

Anders F S Mikkelsen1, Jesper Thygesen2, Joan Fledelius3

  • 1Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

Seminars in nuclear medicine
|March 7, 2025
PubMed
概括

标准化X射线计算机断层扫描 (CT) 协议对于分子成像中的一致图像质量至关重要. 定期审计和协议管理确保最佳的诊断准确性,同时尽量减少患者和工人的辐射剂量.

更多相关视频

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

2.9K
Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
06:53

Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm

Published on: July 23, 2020

5.5K

相关实验视频

Last Updated: May 23, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
09:55

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules

Published on: October 4, 2024

290
High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

2.9K
Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
06:53

Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm

Published on: July 23, 2020

5.5K

科学领域:

  • 医疗成像医学成像
  • 核医学是一种核医学.
  • 放射学 放射学是一门学科.

背景情况:

  • 在分子成像中,X射线计算机断层扫描 (CT) 对于减弱校正 (AC) 和SPECT和PET扫描中的地形数据至关重要.
  • 不一致的CT扫描协议跨制造商和扫描器代挑战实现统一的图像质量,影响诊断和治疗规划.

研究的目的:

  • 审查CT成像参数,获取因素,重建算法和与核医学相关的质量指标.
  • 讨论实施强大的CT协议审查流程,并评估代重建 (IR) 和深度学习 (DL) 等先进技术.

主要方法:

  • 关于CT成像参数和质量指标的文献综述.
  • 对IR和DL进行评估,以提高图像质量和减少剂量.
  • 讨论实施协议审查和审计流程的讨论.

主要成果:

  • 在CT协议中的可变性对图像质量的一致性构成重大挑战.
  • 红外和DL显示出改善图像质量和减少辐射暴露的潜力.
  • 定期审计和协议管理对于保持高成像标准至关重要.

结论:

  • 标准化CT协议和定期进行质量审计对于可靠的分子成像是必要的.
  • 实施本地诊断参考水平和有效的协议管理可确保高质量,低剂量成像服务,遵守ALARA原则.