扫描电子显微镜在体积电子显微镜的物理基础
Mitsuo Suga1,2, Yusuke Hirabayashi3
1Solution Center, JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558, Japan.
Microscopy (Oxford, England)
|March 8, 2025
概括
卷电子显微镜 (vEM) 使用先进的扫描电子显微镜 (SEM) 进行3D生物成像. 了解SEM物理,镜头和探测器是选择最佳VEM数据采集的正确仪器的关键.
科学领域:
- 电子显微镜电子显微镜
- 生物成像技术 生物成像技术
- 生物物理学的生物物理.
背景情况:
- 体积电子显微镜 (vEM) 对于3D生物结构分析至关重要.
- 扫描电子显微镜 (SEM) 的进步现在可以实现高分辨率的vEM.
- 不同的SEM类型为vEM研究提供了明显的优势.
研究的目的:
- 为vEM解释SEM的基础物理.
- 详细说明信号电子生成和检测机制.
- 为了指导选择适当的SEM技术,以实现最佳的vEM成像.
主要方法:
- 在SEM中解释信号电子生成物理.
- 审查不同的SEM目标镜头配置.
- 对VEM的SEM检测系统的分析.
主要成果:
- 在SEM中,高分辨率成像通过特定的物理原理得到了增强.
- 通过优化的SEM设置,可以实现更好的信号检测条件.
- 了解这些因素有助于为vEM选择合适的SEM.
结论:
- 对SEM物理学的全面理解对于有效的vEM至关重要.
- 了解镜头和探测器系统可以优化vEM数据质量.
- 本指南支持研究人员选择最适合他们的vEM需求的SEM.
相关概念视频
Scanning Electron Microscopy
4.1K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.1K
Overview of Electron Microscopy
8.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.5K
Overview of Microscopy Techniques
9.6K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
9.6K
Transmission Electron Microscopy
5.3K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.3K
Electron Microscope Tomography and Single-particle Reconstruction
2.3K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.3K
Preparation of Samples for Electron Microscopy
5.3K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.3K


