基于电动鱼食优化的岛屿微电网的控制设计
M A Ebrahim1, Ahmed S Ragab2, Beshoy Abdou Aziz3
1Electrical Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt. mohamed.mohamed@feng.bu.edu.eg.
Scientific reports
|March 10, 2025
概括
本研究介绍了电动鱼食优化 (EEFO) 技术,以加强岛屿微电网的控制系统. 在调控制器中,EEFO提供了卓越的性能,用于稳定的电压和频率调节,以及无的电网重新连接.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 优化算法 优化算法
背景情况:
- 岛屿微电网由于缺乏惯性和参数不确定性而面临控制挑战.
- 传统的控制方法与高度非线性和相互依存的微电网系统作斗争.
研究的目的:
- 提出一种用于调整微电网控制参数的新型优化技术.
- 提高岛屿微电网的稳定性和性能.
主要方法:
- 开发了电动鱼食优化 (EEFO) 技术.
- 实现了具有比例共振 (PR) 控制器和同步循环的等级控制结构.
- 与粒子群优化 (PSO) 和灰狼优化 (GWO) 进行比较.
主要成果:
- 与公用事业单位和GWO相比,EEFO表现出优越的融合速度和解决方案质量.
- 在最小电压 (2.4%) 和频率 (0.42%) 的情况下实现了有效的主动功率共享.
- 证明电压 (0.25秒) 和频率 (0.53秒) 的最小定位时间.
- 经过验证的无电网重新连接能力.
结论:
- 拟议的EEFO技术有效调整岛屿微电网的控制参数.
- 对于实际的微电网应用,EEFO提供了一个强大的,可行的解决方案,通过模拟和硬件在循环模拟来验证.
相关概念视频
Control of Power Flow
246
There are several methods to control power flow in power systems:
246
Generator Voltage Control
107
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
107
Fast Decoupled and DC Powerflow
148
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
148
Load-frequency control
112
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
112
Induced Electric Fields: Applications
1.5K
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
1.5K
Maximum Power Flow and Line Loadability
91
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
91