一个实验案例的双模式合的能源管理策略为岛屿交流/直流混合微电网
Bin Wei1, Yifan Liu2, Jiahao Duan2
1School of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan, 030024, China. weibin279@163.com.
Scientific reports
|March 10, 2025
概括
本研究介绍了岛屿交流/直流混合微电网的双模式能源管理策略. 它平衡经济运行和稳定性,确保可靠的电力供应,即使有有限的可调节利.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 整合可再生能源的整合
背景情况:
- 由于有限的可调节利,岛屿交流/直流混合微电网面临着平衡经济效率和运营稳定的挑战.
- 现有的能源管理策略往往难以协调这些相互竞争的目标.
研究的目的:
- 为岛屿交流/直流混合微电网提出一种新的双模式合能源管理策略.
- 在微电网运行中有效平衡经济考虑和稳定性要求.
主要方法:
- 一个双模式战略,具有不同的"经济"和"紧急"操作模式.
- 经济模式的双阶段随机预测控制 (SPC) 调度模型.
- 电压/频率 (V/F) 控制单元的电荷状态 (SOC) 监控以触发模式切换以保持稳定性.
主要成果:
- 拟议的战略成功地实现了正常条件下的经济运行.
- 紧急模式确保微电网稳定性,当可调节边缘不足时.
- 现有AC/DC混合微电网的实验验证证证了该战略的有效性.
结论:
- 新的双模式战略为岛屿交流/直流混合微电网提供了全面的最佳能源管理.
- 它有效地管理短期风险,并确保经济效率和稳定.
- 该策略直接适用于现实世界的岛屿交流/直流混合微电网系统.
相关概念视频
Conservation of AC Power
320
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
320
Fast Decoupled and DC Powerflow
148
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
148
Power System Distribution
224
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
224
Power System Three-Phase Short Circuits
71
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
71
Energy Losses in Transformers
818
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
818
Maximum Power Transfer
213
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
213