向着个性化的血压慢性治疗的方向
Germaine Cornelissen1, Yoshihiko Watanabe2, Larry A Beaty1
1Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN, USA.
Biomedical journal
|March 10, 2025
概括
对抗高血压药物的最佳时间仍在争论中. 这项研究发现,根据昼夜血压模式,通过门诊血压监测分析药物管理的个性化,可以优化治疗的有效性.
科学领域:
- 时间生物学 时间生物学
- 药理学 药理学是指药理学的学科.
- 心血管医学 心血管医学
背景情况:
- 服用抗高血压药物的最佳时间尚未得到普遍同意.
- 药物对血压 (BP) 昼夜模式和个体患者反应的影响各不相同.
- 这种变化有助于治疗时间的持续争议.
研究的目的:
- 调查不同抗高血压药物给药时间对24小时血压概况的影响.
- 为了比较早晨和晚上的剂量对BP昼夜模式的影响.
- 探索患者对治疗时间的具体反应.
主要方法:
- 重新分析了从服用五种不同的抗高血压药物的患者获得的7天的门诊血压监测 (ABPM) 数据.
- 血压概况与醒来后1.5小时或每天两次服用药物的比较.
- 分析了从六个不同的给药时间接受洛萨坦/甲的患者获得的ABPM数据.
主要成果:
- 一些抗高血压药物改变了24小时的血压幅度,阶段或波形.
- 在一些患者中,晚上剂量改善了血压幅度,而在其他患者中,早上剂量是有效的.
- 在24小时血压节奏的所有特征中观察到显著的日复一日变化.
结论:
- 建议对抗高血压药物治疗时间进行个性化优化.
- 对多天ABPM数据的时代生物学分析可以指导个性化治疗策略.
- 将治疗时间与健康的昼夜血压模式相匹配,可能会提高治疗结果.
相关概念视频
Errors occurring during blood pressure monitoring
580
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
580
Pre-Procedural Guidelines for Assessing Blood Pressure
518
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
518
Special considerations while measuring blood pressure
694
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
694
Measurement of Blood Pressure
792
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
792
Assessment of blood pressure in brachial artery(one-step method)
550
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
550
Equipments Used To Measure Blood Pressure
782
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
782