概括
本研究介绍了一种双频微带补丁天线传感器,配备一个互补的分裂环共振器 (CSRR),用于精确的实时温度监测. 该传感器在工业应用中表现出高灵敏度和稳定性.
科学领域:
- 电气工程 电气工程
- 材料科学 材料科学 材料科学
- 传感器技术 传感器技术
背景情况:
- 微条纹补丁天线提供适合工业应用的频率稳定性.
- 整合互补分环共振器 (CSRR) 提高对介电变化的灵敏度,并使双共振成为可能.
- 实时温度传感需要具有可调频带的强大的天线设计.
研究的目的:
- 设计和制造双频微带补丁天线传感器,用于准确的实时温度检测.
- 调查CSRR结构参数对传感器性能和频率调节的影响.
- 为了评估传感器的灵敏度,稳定性和可重复性在广泛的温度范围内.
主要方法:
- 一个低调的CSRR结构被集成到一个微条纹补丁天线中.
- 陶基板和印与高温烧结被用于制造.
- 通过模拟和实验测试优化了天线参数和共振频率.
- 通过监测S11曲线从25°C到350°C的变化来分析温度依赖的性能.
主要成果:
- 制造出来的传感器在2.50GHz和3.24GHz时表现出双重共振频率.
- 随着温度的增加,观察到S11曲线的线性偏移.
- 传感器达到183kHz/°C的最大灵敏度,隙深度为-42dB,质量系数为1413.
- 在实验测试中证实了出色的稳定性和可重复性.
结论:
- 开发的双频微带补丁天线传感器有效地实时测量温度.
- 该CSRR集成提供可控制的调整,并增强传感能力.
- 该传感器符合各种工业领域多频段温度测试的实际要求.
相关概念视频
Thermosensation
30.3K
Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
30.3K
Operational Amplifiers
727
The operational amplifier, often referred to as an op-amp, is a multifaceted building block of a circuit. This electronic component functions like a voltage-controlled voltage source and can also be used to create a voltage- or current-controlled current source. The design of an operational amplifier enables it to execute mathematical operations when external components like resistors and capacitors are linked to its terminals. An op-amp has the capacity to sum signals, amplify a signal,...
727
Assessing Body Temperature - Tympanic membrane
556
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
556
Assessing Body Temperature - Oral
708
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
708
Temperature Measurement Sites
1.5K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.5K
Equipments Used to Measure Body Temperature
936
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
936