使用不同软件产品对上呼吸道体积测量的准确性:比较分析
Muhammed Enes Naralan1, Taha Emre Köse2, Merve Gonca3
1Assistant Professor, Recep Tayyip Erdoğan University, Faculty of Dentistry, Department of Oral and Dentomaxillofacial Radiology, Rize, Türkiye.
Dento maxillo facial radiology
|March 14, 2025
概括
与其他软件相比,NemoStudio从形束计算机断层扫描 (CBCT) 图像中测量气道体积的准确性较低. ITK-SNAP和3D Slicer提供了最准确的结果,强调了需要仔细选择软件的必要性.
科学领域:
- 放射学和成像科学 放射学和成像科学
- 生物医学工程 生物医学工程
- 牙和大脸部成像技术
背景情况:
- 精确的气道体积测量从形光束计算机断层扫描 (CBCT) 对于临床诊断和治疗规划至关重要.
- 为了分析CBCT数据,存在各种软件程序,但它们的体积精度可能会有很大的差异.
- NemoStudio是一个常用的软件,但其在气道体积评估中的性能需要详细的评估.
研究的目的:
- 通过使用不同的软件,评估来自CBCT图像的气道体积测量的准确性.
- 将NemoStudio的性能与其他细分工具进行比较,包括NNT Viewer,ITK-SNAP和3D Slicer.
- 用充满水的固体模型作为黄金标准,建立体积准确性的基准.
主要方法:
- 从CBCT数据创建了一个3D打印的气道模型,并扫描了10次.
- 使用NemoStudio,NNT Viewer,ITK-SNAP和3D Slicer进行了半自动细分.
- 体积测量与黄金标准 (充满水的腔) 进行了比较,使用重复测量ANOVA和Bland-Altman图表.
主要成果:
- 与其他软件相比,NemoStudio表现出系统偏差和更高的可变性,导致精度较低.
- ITK-SNAP和3D Slicer展示了与黄金标准的最高一致性.
- NNT Viewer显示了可接受的性能,而统计分析证实了测试软件之间的准确性有显著差异 (P < 0.001).
结论:
- 软件选择对基于CBCT的气道体积测量的准确性产生重大影响.
- 建议使用ITK-SNAP和3D切片器进行更可靠的气道体积分析.
- 标准化方法和细分算法的完善是改善临床一致性的必要条件.
相关概念视频
Respiratory Volumes
Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Application of Integration: Problem Solving
The process of breathing involves the periodic intake and expulsion of air, known as the respiratory cycle, which typically lasts about five seconds. Modeling the volume of air inhaled into the lungs as a function of time provides insight into both the dynamics and efficiency of pulmonary ventilation. This volume is determined by integrating the airflow rate over time, which captures the cumulative effect of air entering the lungs.Sinusoidal Model of AirflowAirflow during respiration is not...