在TRACERS任务上的Cusp Ions (ACI) 分析仪
Stephen A Fuselier1,2, Matthew A Freeman1, Craig A Kletzing3
1Southwest Research Institute, San Antonio, TX USA.
概括
在TRACERS任务上的Cusp离子分析仪 (ACI) 提供了地球磁层尖端离子速度分布函数的详细测量. 这些仪器可以精确检测尖端边界,并描述离子行为的特征.
科学领域:
- 空间物理 空间物理
- 磁层物理 磁层物理
- 等离子体物理学的物理学
背景情况:
- 磁层尖端是太阳风和地球磁层之间能量和粒子转移的关键区域.
- 了解尖端的离子动态对于理解太空天气现象和磁层过程至关重要.
研究的目的:
- 描述TRACERS任务上的Cusp Ions分析仪 (ACI) 仪器的能力.
- 突出ACI测量如何为TRACERS任务的科学目标提供贡献.
主要方法:
- 在旋转平台上使用圆形顶帽静电分析仪,以实现全角覆盖.
- 在低地球轨道上使用两个距离很近的航天器进行全面的数据采集.
- 测量离子速度分布功能具有高频率 (312 ms) 和良好的能量/角度分辨率.
主要成果:
- ACI仪器提供了一个广泛的离子能量范围 (∼8 eV/e到20,000 eV/e),有47个对数能量阶段.
- 实现分数能量分辨率≤10%和即时角分辨率为22.5° × ∼6°.
- 展示检测尖端边界的能力,并以灵敏和精确的态度描述离子步骤.
结论:
- ACI非常适合在磁层尖端对离子行为进行详细的现场测量.
- 这些测量对于我们进一步了解尖端过程及其对太空天气的影响至关重要.
相关概念视频
Mass Analyzers: Common Types
540
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
540
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
605
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
605
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
357
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
357
Mass Analyzers: Overview
556
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
556
Mass Spectrometers
5.0K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.0K
Tandem Mass Spectrometry
843
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
843