对于终端传感器在电源状态监控中的低功耗通信策略
Qingqing Wu1, Yufei Wang1, Di Zhai1
1China Electric Power Research Institute, Beijing 102209, China.
Sensors (Basel, Switzerland)
|March 17, 2025
概括
本研究介绍了一种新的低功耗通信策略,用于电源管道画廊 (PPG) 中的终端传感器. 它确保了可靠的能源供应,避免了通信冲突,加强了电力设备的监控.
科学领域:
- 电气工程 电气工程
- 无线通信无线通信
- 传感器网络 传感器网络
背景情况:
- 电力管道画廊 (PPG) 中的终端传感器对于监测设备状态至关重要.
- 现有的低功耗通信策略遭受电池更换挑战和通信冲突,导致不可靠的电源供应.
- 在PPG中的狭窄空间加剧了电池更换困难和能源损失.
研究的目的:
- 为PPG中的终端传感器提出低功耗通信策略.
- 解决传感器网络中可靠能源供应和通信冲突的挑战.
- 加强PPG中电力设备的状态监控能力.
主要方法:
- 进行了PPG状态监控的需求分析.
- 开发了一个基于认知反散技术的技术框架和系统模型.
- 实现射频能量采集和距离-能量水平合分析,以实现连续电源和避免冲突.
- 为PPG建立了一个无线通信模拟环境.
主要成果:
- 拟议的认知反向散射系统有效地使终端传感器能够连续供应能量.
- 距离-能量水平合分析成功地减轻了传感器之间的通信冲突.
- 模拟验证了拟议策略在加强PPG状态监测方面的有效性.
结论:
- 新的低功耗通信策略为PPG中的终端传感器提供了可靠的能源供应.
- 该方法有效地克服了现有方法的局限性,提高了传感器网络的可靠性.
- 这项研究有助于在封闭的环境中实现更强大,更有效的电力设备监控.
更多相关视频
04:13Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
6.7K
11:21Methodology for Establishing a Community-Wide Life Laboratory for Capturing Unobtrusive and Continuous Remote Activity and Health Data
Published on: July 27, 2018
8.2K
相关概念视频
Energy and Power Signals
227
In an electrical system with a resistor, voltage and current signals facilitate the measurement of power and energy across the resistor. For a continuous-time signal, the total energy over a time interval is defined as the integral of the square of the signal's magnitude over that interval. Mathematically, this is expressed as:
227
Pilot and Numeric Relaying
71
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
71
Power System Distribution
224
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
224
Maximum Power Transfer
196
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
196
Electrical Power
3.0K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.0K
Pulse rhythm
743
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
743
