作为篮球中的基于加速器的追踪设备,Firstbeat体育传感器的单位间可靠性
Daniele Conte1, Ermanno Rampinini2,3, Fabio Trimarchi4
1Department of Movement, Human and Health Sciences, University of Rome "Foro Italico,"Rome, Italy.
International journal of sports physiology and performance
|March 18, 2025
概括
在职业篮球训练中,Firstbeat Sport传感器证明了可靠的运动负载 (ML) 追踪. 这些传感器可以被教练互换使用,以监测球员的外部负载.
科学领域:
- 运动科学 运动科学 运动科学
- 生物力学 生物力学
- 人类运动分析 人类运动分析
背景情况:
- 监测外部负载对于优化训练和预防职业篮球中受伤至关重要.
- 第一节运动传感器提供了一种在训练期间量化运动负载 (ML) 的方法.
研究的目的:
- 评估篮球训练期间从Firstbeat Sport传感器获得的运动负载 (ML) 数据的单位间可靠性.
主要方法:
- 八名男性职业篮球运动员参加了比赛,他们在各种训练练中佩戴了两个Firstbeat Sport传感器.
- 运动负载 (ML) 用Firstbeat体育软件计算了整个会议和特定篮球活动的运动负载.
主要成果:
- 在所有测试条件 (P > .05) 中,传感器之间没有发现ML数据的显著差异.
- 变化系数在2.51%至5.97%之间,类内相关系数在0.98至1.00之间,表明高可靠性.
结论:
- 在职业篮球训练中,Firstbeat Sport传感器对监控运动负载 (ML) 具有可接受的单位间可靠性.
- 这些发现支持可互换使用Firstbeat Sport传感器来跟踪篮球运动员的外部负载.
更多相关视频
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
7.8K
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
326
相关概念视频
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Pulse rhythm
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...