碳点来源于生 officinale Rosc (生),具有静血作用
Wen-Jing Hu1, Ai-Qi Yu1, Hai-Zheng Bi1
1Key Laboratory of Basic and Application Research of Beiyao (Heilongjiang University of Chinese Medicine), Ministry of Education, Heilongjiang University of Chinese Medicine, Harbin, China.
Frontiers in molecular biosciences
|March 19, 2025
概括
碳化生碳点 (CG-CDs) 显示出显著的静血活性. 这些新型纳米粒子通过影响凝血和纤维溶解通路来加速血液凝结并减少出血.
科学领域:
- 生物材料科学 生物材料科学
- 纳米技术纳米技术
- 传统中国医药 传统中国医药
背景情况:
- 是一种传统的中医药,在高温下加工成碳化 (CG).
- 碳化生表现出原生生中没有的静血性质.
研究的目的:
- 为了研究碳化生的静血作用.
- 为了确定碳化生中负责血液静止的特定物质.
主要方法:
- 碳化生碳点 (CG-CDs) 是从碳化生水溶液中合成的.
- 使用小鼠尾部出血和肝损伤模型评估了静血疗效.
- 毛细血管凝血实验评估了凝血时间.
- 研究了它们的作用机制.
主要成果:
- 平均粒子大小为4.07纳米的CG-CD以其石墨结构和元素组成 (C,N,O) 为特征.
- 在动物模型中,CG-CD显著缩短了出血时间,并减少了血液损失.
- CG-CDs调节了凝血参数,增加了血小板数和激活因子 (TXB2,PAI-1),同时降低了抑制剂 (6-keto-PGF1,t-PA).
结论:
- CG-CDs具有显著的静血活性.
- 静血机制涉及到凝血通路的激活和纤维溶解系统的调节.
- CG-CDs代表了治疗出血障碍的一个有前途的治疗药物.
相关概念视频
¹³C NMR: ¹H–¹³C Decoupling
991
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
991
The Carbon Cycle
36.8K
Carbon is the basis of all organic matter on Earth, and is recycled through the ecosystem in two primary processes: one in which carbon is exchanged among living organisms, and one in which carbon is cycled over long periods of time through fossilized organic remains, weathering of rocks, and volcanic activity. Human activities, including increased agricultural practices and the burning of fossil fuels, has greatly affected the balance of the natural carbon cycle.
36.8K
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
991
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
991


