基于同位素稀释液体色谱 (ID-LC-MS/MS) 的候选参考测量程序的开发和验证,用于人类血清中总3,3',5-triiodothyronine的测量
Wenya Li1, Bingling Gao1, Tao Yang1
1Maccura Biotechnology Co., Ltd, Chengdu, 611731, China.
Analytical and bioanalytical chemistry
|March 22, 2025
概括
开发了一种新的,简化的测量血清中三甲氨酸 (T3) 总量的方法,使用同位素稀释液色谱与并列质谱 (ID-LC-MS/MS). 这种SI可追溯的方法增强了甲状腺疾病诊断和测试标准化.
科学领域:
- 临床化学 临床化学
- 分析化学 分析化学
- 质谱测量质量谱测量
背景情况:
- 3,3',5-Triiodothyronine (T3) 对于诊断甲状腺疾病至关重要.
- 现有的T3的参考测量程序 (RMP) 已经使用了20年.
- 提高T3测量的精度和效率对于临床实验室至关重要.
研究的目的:
- 开发和验证一种简化,SI可追溯的血清总T3 (TT3) 候选RMP.
- 通过整合精简的样本准备流程来改进当前的RMP.
- 确保新方法可靠,适合常规测试标准化.
主要方法:
- 使用同位素稀释液体色谱与并联质谱学 (ID-LC-MS/MS) 的方法.
- 一个简化的血清清洁涉及蛋白质沉和干燥.
- 方法验证遵循ISO指南,包括测量不确定性评估.
主要成果:
- 该方法表现出高线性 (0.016到13.086nmol/L) 和低不精确性 (内测0.11.9%,间测0.51.2%).
- 偏差是最小的 (SRM971的0.34至-1.65%),与现有RMP的一致性是很好的 (平均偏差在6%内).
- 测量不确定性被确定为0.022nmol/L和0.120nmol/L对于不同的参考材料.
结论:
- 开发的候选RMP可追溯,可靠,易于使用.
- 这种方法显示出标准化血清T3试验的巨大潜力.
- 它促进了用于甲状腺激素分析的新血清参考材料的开发.
相关概念视频
Synthesis and Regulation of Thyroid Hormones
4.1K
Low blood levels of the thyroid hormones — triiodothyronine (T3) and thyroxine (T4) — signal the hypothalamus to release the thyrotropin-releasing hormone (TRH). TRH then reaches the pituitary gland and stimulates the release of thyroid-stimulating hormone(TSH) into the bloodstream.
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
4.1K
Redox Titration: Iodimetry and Iodometry
990
Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
990
Chemical Shift: Internal References and Solvent Effects
579
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
579


