基于红外热成像的水泄漏温度场的分析和识别
Po Li1,2, Lei Tang3, Shenghang Zhang1
1State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering, Nanjing Hydraulic Research Institute, Nanjing, China.
Scientific reports
|March 28, 2025
概括
红外热成像通过识别低温异常来检测土岩泄漏. 这种技术,特别是无人机,提供快速准确的危险检测,对大安全至关重要.
科学领域:
- 地质技术工程 地质技术工程
- 遥感 遥感 遥感 遥感
- 热分析 热分析
背景情况:
- 泄漏是土岩水中常见的,隐藏的,威胁性的问题.
- 早期发现泄漏对于大的安全和维护至关重要.
研究的目的:
- 引入和验证红外热成像技术,用于检测土岩水中的水泄漏.
- 分析与水泄漏相关的热异常的特征和影响因素.
主要方法:
- 采用红外热成像技术,非接触式检测水泄漏.
- 采用了流热合理论和数值模拟,使用不同的水头和温度差异.
- 在不同条件下分析红外图像特征和温度测量精度.
主要成果:
- 漏导致漏出口处明显的低温异常.
- 低温异常随着水头增加和空气水温差异增加而加剧.
- 无人机捕获的红外图像显示了温度分层,泄漏区域内的温度较低.
结论:
- 红外热成像是一种可行的和有效的技术,用于在土岩中快速,准确地检测泄漏.
- 该技术,特别是与无人机集成时,提高了识别泄漏危险和确保大安全的能力.
相关概念视频
Equipments Used to Measure Body Temperature
2.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
2.1K
Assessing Body Temperature - Temporal Artery
1.6K
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
1.6K