评估不同类型的散装复合材料的聚合收缩,微硬度和固化的深度
Sergen Özdemir1, İlker Ayaz2, Nurgül Çetin Tuncer1
1Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey.
概括
高照射率增加了SonicFill 2 (SCF) 大量填充复合材料的收缩和空隙. 巨大的SO重流 (GHF) 和填充! (FUP) 没有达到目标的4mm深度.
科学领域:
- 牙科材料科学 牙科材料科学
- 聚合物化学 聚合物化学
- 生物材料工程 生物材料工程
背景情况:
- 与传统复合材料相比,散装复合材料提供更快,更容易的放置.
- 了解聚合特性,如收缩,微硬度和治愈深度,对于临床成功至关重要.
- 材料组成和固化参数的变化可以显著影响这些特性.
研究的目的:
- 量化和比较六种不同的散装复合材料的聚合收缩,微硬度和固化深度.
- 评估标准与高辐射水平对这些特性的影响.
- 确定最佳的材料和固化策略,以实现可靠的复合材料修复.
主要方法:
- 六种散装填充复合材料 (SonicFill 2,ViscCalor,Admira Fusion x-tra,Filtek散装填充,填充!,GrandioSO重流) 进行了测试.
- 标本在标准或高辐射下治愈,并使用微计算机断层扫描分析收缩和空隙形成.
- 微硬度测试以0.5mm的间隔确定了固化的深度.
主要成果:
- 在标准照射量下,Admira Fusion x-tra (AFX) 呈现出最高的体积收缩和空隙比.
- 增加的辐射强度显著增加了SonicFill 2 (SCF) 的收缩和空隙 (p<0.05).
- 格兰迪奥SO重流 (GHF) 在最浅的深度 (2.9mm) 显示出最大的微硬度,而VisCalor (VVC),AFX和SCF在5mm以上的深度 (p<0.05) 显示出最大的微硬度.
结论:
- 高辐射加剧了SCF体积收缩和空洞形成.
- 补油!补油!补油!补油!补油!补油! (FUP) 和GHF未能达到推的4mm深度的治愈.
- 材料类型,辐射率和恢复厚度是影响散装复合材料聚合和临床性能的关键因素.
相关概念视频
Drying Shrinkage
74
When hardened concrete is exposed to air with a relative humidity of less than 100 percent, it begins to lose the free water within its capillaries. As this water evaporates, the water initially adsorbed onto the calcium silicate hydrates migrates towards these now empty spaces and eventually evaporates as well. Over time, as more water leaves, the volume of the concrete decreases, a phenomenon known as drying shrinkage.
A portion of this drying shrinkage can be reversed; if the concrete is...
A portion of this drying shrinkage can be reversed; if the concrete is...
74
Shrinkage in Concrete
88
Shrinkage in concrete is primarily due to water loss from evaporation, hydration of cement, or carbonation, leading to a reduction in volume. The volumetric contraction results in volumetric strain in concrete. However, in practice, shrinkage is measured as linear strain, which is one-third of the volumetric strain.
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
88