用于检测三基因的电比度光探针及其在电旋光纤中的应用
Mengyu Chen1, Cuibing Bai1, Wenhui Xue1
1School of Chemistry and Materials Engineering, Anhui Provincial Key Laboratory of Innovative Drug Development and Industrial Integration Jointly Established Discipline, Anhui Provincial Key Laboratory of Green Carbon Chemistry, Engineering Research Center of Biomass Conversion and Pollution Prevention of Anhui Educational Institutions, Fuyang Normal University, Fuyang, Anhui Province 236037, PR China.
概括
一个新的光探针,DPIM,可以快速地在现场检测三基. 这种方法对于在溶液和气相中检测三基来说既便宜又实用.
科学领域:
- 分析化学 分析化学
- 化学传感器 化学传感器
- 材料科学 材料科学 材料科学
背景情况:
- 三素对人类健康和安全构成重大威胁.
- 迫切需要有效,廉价,现场和快速的三基因检测方法.
研究的目的:
- 设计和合成一种用于三基因检测的新型光探针.
- 为了实现三基因的快速,比值识别和量化.
主要方法:
- 基于激发状态分子内质子转移 (ESIPT) 的新光探针 (DPIM) 的设计和合成.
- 开发智能手机检测平台和带探头的测试纸.
- 将探头嵌入纳米纤维中,用于气态三基因监测.
主要成果:
- DPIM实现了三基因的低检测极限 (3.54 × 10−8 M),并且具有很大的斯托克斯转移 (198 nm).
- 该探测器通过智能手机和测试纸张平台实现了廉价,现场和方便的检测.
- 对沙子中的残留三素观察到有效的比度光"打开".
- 通过使用纳米纤维成功监测高特异性的气态三基.
结论:
- DPIM是第一个用于快速,比度检测三基因的光探针.
- 开发的平台为现场三基因检测提供了实际的解决方案.
- 该探测器显示出用于监测溶液和气相中的三基因的优秀应用潜力.
相关概念视频
Photoluminescence: Applications
346
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
346
Labeling DNA Probes
8.1K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.1K
Fluorescence and Phosphorescence: Instrumentation
492
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
492