概括
识别关键电网节点对于防止因风力发电集成增加而导致的停电至关重要. 本研究引入了一种动态评估方法,用于评估节点漏洞,提高电网稳定性和可靠性.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 电网稳定性 电网稳定性
背景情况:
- 越来越多的风能集成需要强大的方法来识别电网漏洞.
- 系统不稳定性和线路过载是现代电网中的关键问题.
研究的目的:
- 为评估电网节点漏洞提出一个动态综合评估方法.
- 开发风力发电网连接系统的综合评估模型.
- 确定影响系统稳定性和故障率的关键节点.
主要方法:
- 使用结构和状态特征,构建了一个用于节点漏洞的综合索引集.
- 采用改善的权重功率率指数用于不稳定性和超载.
- 使用分析层次过程 (AHP) 和CRITIC方法计算主观和客观权重.
- 用达格姆-吉尼系数进行系统同质性评估.
- 应用了VIKOR方法来对关键节点进行排序.
主要成果:
- 开发并验证了用于电网节点漏洞的动态综合评估方法.
- 成功确定了风力发电系统中影响和故障率高的关键节点.
- 在经过修改的IEEE-118测试系统上证明了该方法的可行性.
结论:
- 拟议的动态评估方法有效地评估了风能集成系统中的电网节点漏洞.
- 这种方法可以更好地识别弱点,有助于提高电网稳定性和可靠性.
- 该方法为电力系统运营商提供了一种有价值的工具,以防止重大停电.
相关概念视频
Fast Decoupled and DC Powerflow
139
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
139
Power System Three-Phase Short Circuits
68
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
68
Wind Turbine Machine Models
92
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
92
Power System Distribution
219
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
219
Maximum Power Flow and Line Loadability
90
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
90
The Power Flow Problem and Solution
144
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
144