微量生物标志物分析的电化学生物传感方法:一篇综述
Baorong Zhang1, Zhuomin Zhang1, Gongke Li1
1School of Chemistry, Sun Yat-sen University, Guangzhou, China.
Critical reviews in analytical chemistry
|April 7, 2025
概括
电化学生物传感为微量生物标志物提供了灵敏,便携且具有成本效益的分析. 这篇评论详细介绍了探测材料和检测离子,病毒和RNA的策略的进展.
科学领域:
- 电化学 电化学 电化学
- 生物感应是一种生物感应.
- 分析化学 分析化学
背景情况:
- 电化学生物传感为生物标志物分析提供高灵敏度,便携性和快速响应.
- 近年来,这些方法取得了重大进展和广泛应用.
- 专注于过去十年的发展.
研究的目的:
- 系统地审查电化学生物传感用于微量生物标志物分析的最新进展.
- 突出探测器准备和生物传感策略的进展.
- 总结应用程序并讨论未来的前景.
主要方法:
- 在过去十年中,专注于电化学生物传感发展的文献综述.
- 探针制备技术的讨论,包括金属协调材料,纳米材料,有机氧化还原材料和聚合物纳米复合材料.
- 分析电化学DNA,体和免疫生物感应策略.
主要成果:
- 探头材料的进步提高了电化学生物传感能力.
- 新的电化学DNA,aptamer和免疫生物感应策略已经开发出来.
- 对金属离子,病毒生物标记物和非编码RNA的成功应用已经得到证明.
结论:
- 电化学生物传感是一种快速发展的领域,对微量生物标志物分析具有重大潜力.
- 对探头设计和传感策略的持续研究将进一步提高生物分析能力.
- 未来的工作应该解决优化性能和扩大生物分析和电化学应用的挑战.
相关概念视频
Electrogravimetric Analysis: Overview
164
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
164
Interfacial Electrochemical Methods: Overview
207
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
207
Potentiometry: Membrane Electrodes
320
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
320
High-Performance Liquid Chromatography: Types of Detectors
383
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
383
Voltammetry: Stripping Methods
141
Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
141
Capillary Electrophoresis: Instrumentation
152
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
152