药剂师领导的员工健康高血压计划的描述,使用远程监控设备
Megan Gushrowski1, Michael J Rush2, Karen L Kier1
1Ohio Northern University HealthWise, Ada, OH, USA.
概括
一个药剂师领导的健康计划使用远程监控改善了员工的高血压控制. 该计划涉及生活方式教育和药物建议,导致血压显著降低.
科学领域:
- 卫生科学 卫生科学 卫生科学
- 临床药房 临床药房
- 预防医学 预防医学
背景情况:
- 员工高血压造成严重的健康和经济负担.
- 工作场所健康计划可以有效地管理诸如高血压等慢性疾病.
- 远程监控技术为患者管理和参与提供了新的途径.
研究的目的:
- 描述药剂师领导的高血压管理员工健康计划的设计,实施和影响.
- 评估工作场所环境中远程血压监测的有效性.
- 评估药剂师在改善员工血压控制中的作用.
主要方法:
- 这项研究涉及一所私立大学的雇员和患有高血压的医疗保险受益者.
- 参与者获得了远程血压监测设备,并参与了药剂师咨询 (面对面或远程医疗).
- 药剂师提供生活方式修改教育,并向初级保健提供者提出药物建议.
主要成果:
- 招募了24名参与者,其中75%的人在基线时患有不受控制的高血压 (SBP 134 mmHg,DBP 85 mmHg).
- 3个月后,39%最初无法控制血压的参与者实现了他们的目标,平均降低了8.9 mmHg SBP和7.8 mmHg DBP.
- 药剂师对药物改变的建议被初级保健提供者接受了70%的比例.
结论:
- 一个由药剂师领导的员工健康计划,包括远程监控,有效地改善了血压控制.
- 生活方式修改教育和与初级保健提供者合作的药物管理是成功的关键组成部分.
- 该模型展示了基于工作场所的干预措施管理高血压和提高员工健康的潜力.
更多相关视频
相关概念视频
Errors occurring during blood pressure monitoring
573
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
573
Pulse rhythm
725
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
725
Assessing Blood pressure in the Leg
1.7K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
1.7K
Equipments Used To Measure Blood Pressure
767
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
767
Pre-Procedural Guidelines for Assessing Blood Pressure
515
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
515
Assessment of blood pressure in brachial artery(one-step method)
549
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
549