室内评估一个温度控制的凝智能转向系统
Zhifeng Luo1,2, Qunlong Wu1,2, Weiyu Chen1
1School of Petroleum and Natural Gas Engineering, Southwest Petroleum University, Chengdu 610500, China.
Nanomaterials (Basel, Switzerland)
|April 11, 2025
概括
这项研究介绍了中国博海油田的智能转移技术. 该方法通过平衡异质水库中的流体分布来改善石油回收.
科学领域:
- 石油工程是石油工程中的一个.
- 储水库工程 储水库工程
- 地质地质地质地质地质地
背景情况:
- 博海SZ36-1油田是中国最大的海上油田,拥有异质的高度,高透度的水库.
- 扩展的注入水改变了水库的孔隙结构,增加了异质性,并降低了传统生产方法的有效性.
研究的目的:
- 开发和验证用于异质海上油库的智能转移和平衡解锁技术.
- 为应对不断变化的水库异质性和生产效率下降所带来的挑战.
主要方法:
- 实施温度控制的转移系统,以阻断主导流通道.
- 确保处理液体的均分配,同时保持水库的完整性.
- 在容器内使用"液体-固体-液体"相位过渡.
主要成果:
- 转移系统表现出良好的注射性和可控制的参数 (固化时间,相变温度,兼容性).
- 该技术实现了高插电强度,快速插电速度和显著的转移效应.
- 建筑要求得到满足,注射强度中等.
结论:
- 智能转移和平衡解锁技术在科学上是有效的,并且对于异质水库来说是可行的.
- 这项技术有效地提高了在具有挑战性的油田环境中流体的分配和生产.
- 该系统为优化成熟的海上油田回收提供了一种新的解决方案.
相关概念视频
Equipments Used to Measure Body Temperature
915
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
915
Assessing Body Temperature - Tympanic membrane
545
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
545
Assessing Body Temperature - Oral
694
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
694
Assessing Body Temperature - Temporal Artery
505
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
505