一般化的酒-兰伯特定律用于评估异质防晒膜的吸收
Etienne Lepoivre1, Sylvain Augé1, Frédéric Nunzi2
1Centre de Recherche Paul Pascal (CRPP), UMR CNRS 5031, Université de Bordeaux, Pessac 33600, France.
ACS applied materials & interfaces
|April 11, 2025
概括
这项研究揭示了防晒膜的不均性如何影响体外阳光保护因子 (SPF) 的测量. 一个新的模型解释了吸收性,厚度和均性,提高了防晒测试的准确性.
科学领域:
- 化品科学 化品科学
- 材料科学 材料科学 材料科学
- 频谱学是一种光谱学.
背景情况:
- 膜异质性在防晒的影响在体外太阳保护因子 (SPF) 测量.
- 目前的方法很难在体内和体外相对应的SPF,特别是高的SPF值.
研究的目的:
- 调查防晒膜异质性在体外SPF的起源和影响.
- 开发一个日晒吸收度和厚度的通用模型.
- 为了提高SPF体外测量的可复制性和一致性.
主要方法:
- 紫外线摄影和湿度测量,以分析PMMA板上的防晒形态.
- 用马分布用于厚度的不均样本的比尔-兰伯特定律的概括.
- 基于线性衰减系数的分析模型的开发.
主要成果:
- 建立了防晒膜的吸收率,厚度和均性之间的分析关系.
- 该模型成功地区分了传播质量和吸收潜力.
- 对三种不同的防晒配方进行了实验验证.
结论:
- 开发的模型解释了体内和体外SPF测试之间的差异.
- 这种方法为更准确和可靠的体外SPF测量提供了途径.
- 这些发现可以有助于开发更有效的防晒产品.
相关概念视频
UV–Vis Spectroscopy: Beer–Lambert Law
1.7K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The...
1.7K
UV–Vis Spectrum
1.0K
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
1.0K
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
257
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
On...
257
UV–Vis Spectrometers
1.2K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.2K
Spectrophotometry: Introduction
2.8K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
2.8K