相关实验视频
Updated: May 14, 2025

08:20
In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
5.9K
基于智能CO2传感器网络的野火预警系统
Alessio De Rango1, Luca Furnari1, Fabio Cortale1
1Department of Environmental Engineering, University of Calabria, Rende, 87036 Cosenza, Italy.
Sensors (Basel, Switzerland)
|April 12, 2025
概括
一个新的智能二氧化碳 (CO2) 传感器网络与人工智能 (AI) 模型显著改善了野火早期检测. 这种由人工智能驱动的系统比传统方法更快地激活更多的传感器,帮助消防工作.
科学领域:
- 环境科学 环境科学
- 计算机科学 计算机科学
- 风险管理 风险管理
背景情况:
- 气候变化加剧了野火风险,特别是在地中海等容易干旱的地区.
- 有效的野火管理需要先进的战略和技术整合.
- 早期检测对于减轻野火损害和支持应对行动至关重要.
研究的目的:
- 提出和评估一个智能二氧化碳 (CO2) 传感器网络,用于野火早期预警.
- 开发和比较人工智能 (AI) 模型,以使用二氧化碳数据增强火灾检测.
- 评估系统在现实环境中的有效性及其对灭火的支持.
主要方法:
- 部署一个通过云平台连接的二氧化碳传感器网络,用于数据管理.
- 开发了三种人工智能模型:自动编码器 (AEs) 和长短记忆器 (LSTM).
- 与44个传感器的受控野火实验中基于非AI值模型的AI模型的比较.
主要成果:
- 人工智能模型,特别是LSTM,与非人工智能模型相比,从二氧化碳数据中提取了更有价值的信息.
- 人工智能系统在更短的时间内激活了多达56%的传感器.
- 该系统成功地追踪了风力模式影响的潜在火线传播.
结论:
- 拟议的智能二氧化碳传感器网络与人工智能显著提高了早期野火检测能力.
- 人工智能模型改善了传感器数据的分析,从而导致更快,更全面的警报.
- 这项技术为改善野火风险管理和支持消防行动提供了有价值的工具.
相关概念视频
Applications of GIS: Disaster Management and Emergency Response
24
Geographic Information System (GIS) technology is essential for risk identification, action prioritization, and resource optimization in critical situations like flooding and earthquakes. By integrating spatial and demographic data, GIS provides a comprehensive framework for emergency response.GIS integrates data layers, like rainfall intensity, topography, elevation profiles, and river levels, to model high-risk flood zones. These layers assess areas susceptible to flooding based on their...
24
Hazard Rate
75
The hazard rate, also known as the hazard function or failure rate, is a statistical measure used to describe the instantaneous rate at which an event occurs, given that the event has not yet happened. From a probabilistic perspective, it represents the likelihood that a subject will experience the event in a very small time interval, conditional on surviving up to the beginning of that interval. In terms of frequency, the hazard rate can be viewed as the ratio of the number of events to the...
75
Signal and System
596
A signal x(t) is a set of data or a time function representing a variable of interest. Signals typically convey information about a phenomenon, such as atmospheric temperature, humidity, human voice, television images, a dog's bark, or birdsongs. More generally, a signal can be a function of more than one independent variable. For instance, images depend on horizontal and vertical positions and can be regarded as two-dimensional signals. However, this text will focus on one-dimensional...
596
Design Example: Automobile Ignition System
193
The automobile's ignition system plays a vital role by ensuring the timely ignition of the fuel-air mixture in each cylinder. This ignition is facilitated by a spark plug, which is composed of two electrodes separated by an air gap. A spark forms across this air gap when a substantial voltage is generated between the electrodes, leading to the ignition of the fuel.
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
193
Pilot and Numeric Relaying
70
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
70
Radial System Protection
85
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
85