适应性周期性速度波动抑制永久磁体压缩机驱动器的周期性速度波动抑制
Chenchen Zhang1, Yang Yang1, Yimin Gong1
1College of Physics, Jilin University, Changchun 130012, China.
Sensors (Basel, Switzerland)
|April 12, 2025
概括
本研究引入了一种适应方法,以抑制由扭矩变化引起的单旋转压缩机的转速波动. 这种新的方法确保了压缩机在各种条件下更顺地运行.
科学领域:
- 工程 工程师 工程师 工程师
- 控制系统 控制系统
- 机械工程 机械工程
背景情况:
- 单旋转压缩机由于周期性负载扭矩变化而经历了显著的转速波动.
- 这些速度波动可能会对压缩机性能和操作稳定性产生负面影响.
研究的目的:
- 为单旋转压缩机提出和验证适应性周期性转速波动抑制方法 (APSFSM).
- 通过减轻特定频率的干扰来增强压缩机转速调节.
主要方法:
- 拟议的APSFSM将低频干扰的比例积分 (PI) 调节器与特定频率干扰的递归高斯-牛顿 (RGN) 算法相结合.
- RGN组件采用基于角度的策略,以实现更流,更快速的速度调节,适应频繁的操作变化.
- 该方法根据实时速度错误自适应地调整补偿电流的振幅和相位.
主要成果:
- 在650W压缩机平台上的实验验证证明了APSFSM的有效性.
- 该方法成功地抑制了不同操作条件下的速度波动.
- 该RGN算法显示了对系统相位转移的稳定性,确保了稳定的性能.
结论:
- 该APSFSM有效地抑制了单旋转压缩机的转速波动.
- 适应性,以角度为基础的RGN方法提供了更流,更强大的速度调节.
- 这种方法为压缩机的运行稳定性和性能提供了显著的改善.
相关概念视频
Time-Domain Interpretation of PD Control
74
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
74
Frequency-Domain Interpretation of PD Control
83
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
The proportional control gain, combined with the...
83
Turbine-Governor Control
122
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
122
Load-frequency control
96
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
96
Magnetic Damping
395
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
395
Simplified Synchronous Machine Model
159
The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
In this model, each generator is connected to a...
159


