一个新的生物发光探针用于检测真实食品样本中的甲
Ziyao Chen1, Jie Zhong1, Zhangyan Zhu1
1Department of Pharmaceutical Engineering, College of Food and Bioengineering, Xihua University, Chengdu 610039, China.
概括
一个新的生物发光探头FA-Fluc能够快速量化食品和生物样本中的甲 (FA). 这种敏感的方法提供了一个启动信号,用于检测各种矩阵和实时成像中的FA.
科学领域:
- 分析化学 分析化学
- 生物化学 生物化学
- 化学生物学 化学生物学
背景情况:
- 甲 (FA) 是一种反应性碳基物种 (RCS),需要敏感的检测方法.
- 对于复杂样本,现有的FA量化方法可能耗时或缺乏效率.
研究的目的:
- 开发一种用于甲检测的新型,快速和高效的生物发光探针.
- 为了验证探测器在各种食物和生物矩阵中的性能,包括实时成像.
主要方法:
- 开发一种生物发光探针 (FA-Fluc),使用同氨酸将火D-luciferin.
- 使用aza-Cope重组,在与FA.反应时激活生物发光反应.
- 测试探头选择性与其他RCS相比,并使用乙乙和HPLC方法验证结果.
主要成果:
- FA-Fluc的检测极限为0.047ppm,反应时间快4小时.
- 探测器成功量化了海鲜,农产品和过程中的FA.
- 与其他RCS相比,FA具有很高的选择性,结果与已知的方法相比.
结论:
- FA-Fluc是第一个生物发光的甲探测器,提供了一种敏感和选择性的检测方法.
- 该探针在复杂的食品样本中有效量化FA,并使活细胞和动物的实时成像成为可能.
更多相关视频
00:07Measuring Interactions between Fluorescent Probes and Lignin in Plant Sections by sFLIM Based on Native Autofluorescence
Published on: January 2, 2020
5.5K
05:49Tracking Microbial Contamination in Retail Environments Using Fluorescent Powder - A Retail Delicatessen Environment Example
Published on: March 5, 2014
11.0K
相关概念视频
Labeling DNA Probes
8.1K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.1K
Photoluminescence: Applications
341
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
341