揭开一个"干水龙头"的评估的神秘性
Shalini Singh1, Erna Ahsan2, Gayathri Saravanan1
1All India Institute of Medical Sciences Rishikesh, Rishikesh, India.
Journal of hematopathology
|April 15, 2025
概括
干水龙头,或骨髓吸血失败,往往是由于潜在的病理,而不仅仅是技术. 急性白血病是常见的原因,强调了干水龙头的诊断重要性.
科学领域:
- 血液学 血液学 血液学
- 病理学 病理学 病理学
- 诊断医学 诊断医学 诊断医学
背景情况:
- 干水龙头,定义为骨髓血液构成元素的吸收失败,经常归因于技术错误.
- 然而,潜在的骨髓病理也可能导致干水龙头,需要进一步调查.
研究的目的:
- 为了调查骨髓吸管中干水龙头的原因.
- 评估干水龙头在诊断骨髓疾病中的临床相关性.
主要方法:
- 在一年内对1060个骨髓吸收物进行了回顾性观察性研究.
- 通过特雷芬活检确定最终诊断,不包括次优样本.
- 分析了125例 (11.8%) 被确定为干水龙头的病例.
主要成果:
- 只有16%的干水龙头被归因于基于适当的三胺活检的错误技术.
- 基本的骨髓病理在84%的干水龙头病例中被确定.
- 急性白血病是干的最常见原因 (32.8%).
结论:
- 干水龙头经常表明有重大潜在的骨髓病理,而不仅仅是技术问题.
- 实验室应审查干水龙头病例,与特雷芬活检相关联,以确定原因.
- 干燥的水龙头应该被认为是潜在的骨髓疾病的诊断警报.
相关概念视频
Testing Water Quality
92
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
92
Errors in Taping
17
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
17
Taping Over Different Ground Profiles
18
Taping over varying ground profiles requires careful adaptation to achieve accurate measurements. On smooth, level ground with minimal vegetation, the tape can rest directly on the ground. Here, the taping team, typically consisting of a head and a rear tapeman, coordinates their positions with clear communication. The rear tapeman holds the tape at the starting point and guides the head tapeman toward a range pole placed beyond the endpoint, using hand or voice signals to ensure alignment.On...
18
Flow Table Test
98
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
98
Single Pipe Systems
62
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
62
Design Example: Designing a Residential Plumbing System
160
The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
160


