相关实验视频
Updated: May 21, 2026

19:44
A Tactile Automated Passive-Finger Stimulator (TAPS)
Published on: June 3, 2009
尖:一个基于Arduino的低成本和开放访问的触发器,用于精确控制TMS设备
Giuseppe Ippolito1,2, Thomas Quettier1, Sara Borgomaneri1
1Center for Studies and Research in Cognitive Neuroscience, Department of Psychology "Renzo Canestrari", Cesena Campus, Alma Mater Studiorum, Università Di Bologna, 47521, Cesena, Italy.
Behavior research methods
|April 15, 2025
概括
这项研究介绍了Silicon Spike,这是一个低成本的触发器,用于跨磁刺激 (TMS). 它可以达到微秒的精度,在神经科学实验中提供精确的脉冲传递.
科学领域:
- 神经科学是一个神经科学.
- 生物医学工程 生物医学工程
背景情况:
- 跨磁刺激 (TMS) 在神经科学中至关重要.
- 由于计算机处理器负载,现有的触发器具有时间不确定性.
- 重复的TMS和双线圈协议需要高时间精度.
研究的目的:
- 开发一种低成本,可重复的TMS触发器.
- 克服当前触发系统的时间限制.
- 确保TMS脉冲传输的精确时间.
主要方法:
- 使用一个Arduino Uno R4 Minima来构建"尖"设备.
- 在各种计算机负载条件下测试了脉冲传递精度.
- 在双线圈,重复和模式的TMS协议中评估性能.
主要成果:
- 在所有测试的TMS协议中实现了极高的精度 (<0.022 ms).
- 证明了各种延迟的微不足道的时间错误.
- 在TMS脉冲传输中确认了微秒精度.
结论:
- 尖为TMS定时提供了一个简单,精确和低成本的解决方案.
- 该设备克服了处理器依赖的触发系统的局限性.
- 开源硬件和代码促进了广泛的采用和可重复性.
相关概念视频
LC Circuits
2.4K
An LC circuit consists of an inductor and a capacitor, either in series or parallel. Consider a charged capacitor connected with an inductor in series. Before the switch is closed, all the energy of the circuit is stored in the electric field of the capacitor. When the switch is closed, the capacitor begins to discharge, producing a current in the circuit. The current, in turn, creates a magnetic field in the inductor. Because of the induced emf in the inductor, the current cannot change...
2.4K
Clamper Circuit
349
A clamper circuit, also known as a DC restorer, represents a specialized variant of the rectifier circuit, notable for its method of taking the output across the diode rather than the capacitor. This configuration lends to several distinctive applications, particularly in handling square wave inputs.
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to...
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to...
349
Electro-mechanical Systems
902
Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
902
PI Controller: Design
170
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
170
Overcurrent Relays
65
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
65
Differential Relays
94
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
94