低频声调的最新技术:强度增强和方向控制
Jingsong Xu1, Yunfeng Ye1, Tao Dong1,2
1State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, School of Instrument Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China.
Advanced science (Weinheim, Baden-Wurttemberg, Germany)
|April 17, 2025
概括
声学超材料能够精确控制低频声波,增强强度和方向性,用于医学和通信应用. 本综述探讨了开发高效,小型化的超低频声学设备的先进技术.
科学领域:
- 声学 声学 在声学方面
- 材料科学 材料科学 材料科学
- 波浪物理 波浪物理
背景情况:
- 高强度,定向的低频声源对于医疗治疗,水下通信和环境监测至关重要.
- 低频波的长波长和衍射特性对方向控制和强度增强提出了挑战.
- 声学超材料提供低频声波的亚波长操纵,提高设备性能.
研究的目的:
- 系统地审查实现高强度发射和低频声波定向控制的方法.
- 为了比较各种现有技术的优缺点.
- 讨论将这些方法扩展到用于先进设备开发的低声频段.
主要方法:
- 对当前技术的审查,重点是源设计和传播过程调制.
- 分析采用声学共振,聚焦和相位控制的方法.
- 探索用于低波长波浪操纵的声学元材料应用.
主要成果:
- 现有的低频声波控制技术存在低能效,方向性差,带宽有限等问题.
- 声学超材料有望克服这些局限性.
- 需要进一步的研究,以将目前的方法扩展到超低频率.
结论:
- 声学超材料是开发先进的低频声学设备的关键.
- 在低频声控制中需要提高能源效率,定向性和带宽.
- 本综述为创建小型化,高效和定向的超低频声学设备提供了见解.
相关概念视频
Frequency-Domain Interpretation of PD Control
80
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
The proportional control gain, combined with the...
80
Design Example
308
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
308
Intensity Of Electromagnetic Waves
4.3K
The energy transport per unit area per unit time, or the Poynting vector, gives the energy flux of an electromagnetic wave at any specific time. For a plane electromagnetic wave with E0 and B0 as the peak electric and magnetic fields and traveling along the x-axis, the time-varying energy flux can be given by the following equation:
4.3K
Time and frequency -Domain Interpretation of Phase-lag Control
72
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
72
Time and frequency -Domain Interpretation of Phase-lead Control
67
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
67
Load-frequency control
93
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
93