生理节奏的优点生理节奏的优点
Ilaria Finamora1, Carlo Colaiaco1, Karim Mahfouz1
1Cardiology Unit, G.B. Grassi Hospital, Rome, Italy.
概括
导电系统节奏为传统节奏提供了一个生理学上的替代方案,可能降低心力衰竭风险. 像His捆绑节奏和左捆绑分支区域节奏这样的技术显示出希望,但需要仔细的患者选择和操作人员技能.
科学领域:
- 心脏病学 心脏病学
- 电力生理学 电力生理学
- 医疗器械 医疗器械
背景情况:
- 传统的右心室节奏与心肌病和心力衰竭有关.
- 需要使用替代步调方法来改善患者的治疗结果.
研究的目的:
- 评估传导系统节奏 (CSP) 作为传统节奏的生理替代方案.
- 为了比较他的捆绑节奏和左捆绑分支区域节奏 (LBBAP) 对于减少喷射分数和异步的患者.
主要方法:
- 审查他的捆绑节奏和LBBAP技术,他们的优点,缺点和电气参数.
- 分析患者选择标准,操作员学习曲线和并发症率.
- 考虑目前欧洲心脏病学会 (ESC) 关于CSP的指导方针.
主要成果:
- 他的捆绑节奏实现了本地QRS复杂,但在技术上具有挑战性.
- 在技术上,LBBAP更简单,但与机械并发症和更广泛的QRS有关.
- 通过仔细的患者选择和培训,CSP是安全有效的,尽管其并发症率比传统节奏更高.
结论:
- 导电系统节奏,包括他的捆节奏和LBBAP,提供生理节奏的好处.
- 目前的指导方针在特定场景中建议CSP,例如重同步治疗失败或AV阻塞和减少射出分数的患者.
- 需要进一步的研究,以充分定义CSP在心脏节拍中的作用.
相关概念视频
Pulse rhythm
717
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
717
Pulse
385
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
385
Equipments Used To Measure Blood Pressure
763
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
763
Regulation of Pulse
1.1K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
1.1K
Decreased pulse rate
515
Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
515
Special considerations while measuring pulse
540
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
540