分布弹性二次控制策略考虑DC微电网的经济调度:动态事件触发机制
IEEE transactions on cybernetics
|April 18, 2025
概括
本研究介绍了DC微电网的统一分布式弹性控制策略,通过使用动态事件触发机制,在网络攻击和有限带宽的情况下增强电压恢复和经济调度.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 电力系统 电力系统
背景情况:
- 由于网络攻击和通信带宽限制,直流微电网面临二次控制方面的挑战.
- 现有的控制策略可能无法在不利条件下充分解决电压稳定性和经济调度问题.
研究的目的:
- 为直流微电网提出统一的分布式弹性控制战略.
- 为了实现同时恢复电压和最佳功率分配 (经济调度).
- 在网络攻击和有限的通信带宽下增强微电网性能.
主要方法:
- 集成动态事件触发机制 (DETM) 与分布式控制协议.
- 使用分布式平均电压估计器和PI控制器的电压调节器的设计.
- 开发一个具有分布式最佳功率控制器和PI控制器的功率调节器.
- 使用利亚普诺夫稳定性和凸起式优化对收和最佳性的分析.
主要成果:
- 拟议的战略有效地将微电网电压恢复到适当的水平.
- 即使在网络攻击的情况下,也保持了最佳的功率分配 (经济调度).
- 动态事件触发机制可以降低通信负载,同时确保系统性能.
- 案例研究证实了DC微电网的增强安全性,稳定性,适应性和经济性.
结论:
- 统一的分布式弹性控制策略对于DC微电网是有效的.
- 该方法增强了微电网对网络攻击和通信限制的弹性.
- 该战略确保了DC微电网的稳定运行和经济效率.
相关概念视频
Secondary Distribution
68
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
68
Fast Decoupled and DC Powerflow
128
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
128
Reclosers and Fuses
71
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
71
Distribution Reliability and Automation
91
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
91
Load-frequency control
93
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
93
Radial System Protection
83
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
83