对于三相光伏系统的无变压器增压逆变器的调制和控制:全面分析
Mostafa Wageh Lotfy1, Ramadan Mahmoud Mostafa2, Haitham S Ramadan3,4
1Department of Process Control Technology, Faculty of Technology and Education, Beni-Suef University, Beni Suef, Egypt. dr.mostafawag@techedu.bsu.edu.eg.
Scientific reports
|April 23, 2025
概括
本研究比较了无变压器光伏系统的三种功率转换器配置. 准Z源逆变器和分割源逆变器表现出与两级直流-直流-交流转换器相比具有竞争力的性能.
科学领域:
- 电气工程 电气工程
- 可再生能源系统可再生能源系统
- 电力电子 电力电子 电力电子
背景情况:
- 无变压器光伏 (PV) 系统对于高效的太阳能转换至关重要.
- 需要先进的功率转换器拓来提高光伏系统的性能和降低成本.
研究的目的:
- 分析和比较三相无变压器光伏系统的三种不同的功率转换器配置的性能.
- 评估每个配置的拓要求,调制策略和输出电压控制.
主要方法:
- 详细分析了两级直流-直流-交流转换器,单级近似Z源逆变器 (qZSI) 和分割源逆变器 (SSI).
- 考虑理想和寄生条件的性能评估,包括设备应力,被动元件和效率.
- 通过模拟和实验测试进行验证.
主要成果:
- 在三个拓中对组件的电压和电流应力进行比较.
- 对无变压器光伏应用的效率和适用性进行评估.
- 根据性能指标确定最佳配置.
结论:
- 准Z源逆变器 (qZSI) 和分割源逆变器 (SSI) 证明了传统两级转换器的可行替代品.
- 性能分析为在无变压器光伏系统中选择合适的功率转换器提供了洞察力.
更多相关视频
相关概念视频
Generator Voltage Control
87
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
87
Generation of Three-Phase Voltage
320
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
320
Control of Power Flow
242
There are several methods to control power flow in power systems:
242
Reducing Line Loss
130
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
130
Transformers in Distribution System
96
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
96
Turbine-Governor Control
114
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
114