在老年人关节骨折手术中,手术内血压变化和术后狂妄的相关性
Peng Yang1, Yu Fan2, Wanyun Tang3
1Department of Anesthesiology, Zigong First People's Hospital, 643000, Zigong, People's Republic of China.
Scientific reports
|April 29, 2025
概括
在老年关节骨折患者中,手术后血压变化 (BPV) 的增加与术后狂妄症 (POD) 的风险更高有关. 管理BPV可能有助于减少POD发病率.
科学领域:
- 老年麻醉学老年麻醉学
- 外科手术患者的结果
- 神经临界护理是指神经临界护理.
背景情况:
- 手术后痴呆症 (POD) 是接受关节骨折手术的老年患者的常见并发症.
- 术后血压变化 (BPV) 被认为是POD的潜在危险因素.
- 优化管理策略以减轻这种脆弱人群中POD风险至关重要.
研究的目的:
- 为了研究手术内血压变化 (BPV) 与手术后狂妄症 (POD) 在经历骨折手术的老年患者中的发生率之间的关联.
- 确定高BPV是否是POD的独立预测因素.
- 探索BPV和POD之间的剂量反应关系和潜在效果修饰因素.
主要方法:
- 对1002名接受关节骨折手术的老年患者进行了回顾性分析.
- 使用平均动脉压变化系数 (CV-MAP) 来量化手术内血压.
- 使用了倾向得分匹配 (PSM),多变量逻辑回归和受限立方线 (RCS) 分析.
主要成果:
- 手术后痴呆症 (POD) 在19.8%的患者中发生.
- 较高的手术内BPV (CV-MAP>10%) 与POD发病率的增加显著相关 (25.2%与PSM后18.9%相比,p=0.032).
- 升高的CV-MAP是POD的独立预测因子 (aOR: 1.45,95%CI 1.03-2.03),观察到非线性正相关性.
结论:
- 在老年关节骨折患者中,增加的手术内血压变化 (BPV) 与术后狂妄症 (POD) 的风险增加独立相关.
- 非线性效应和与年龄和ASA分类等因素的相互作用改变了这种关联.
- 在手术期间个性化血压管理对于降低POD风险在这个患者群体中很重要.
相关概念视频
Pre-Procedural Guidelines for Assessing Blood Pressure
509
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
509
Assessing Blood pressure using a doppler ultrasound
1.1K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.1K
Special considerations while measuring blood pressure
689
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
689
Assessment of blood pressure in brachial artery(two-step method)
617
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
617
Measurement of Blood Pressure
613
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
613
Errors occurring during blood pressure monitoring
565
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
565