基于基于模块化多层转换器的HVDC电网的IVRW触角外面积比率的非单元保护
Yao Sun1, Yanfang Fan2, Junjie Hou3
1The School of Electrical Engineering, Xinjiang University, Xinjiang, 830017, China.
Scientific reports
|April 29, 2025
概括
对于直流电网,一种新的非单元保护方法使用了初始故障电压逆波 (IVRW) 触角外面积比. 这种方法有效地识别出故障区域,即使故障阻力和噪声很高.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 故障分析,故障分析.
背景情况:
- 模块化多层转换器 (MMC) 在直流电网中至关重要.
- 在MMC中快速发生故障需要快速保护.
- 现有的基于移动波的保护与故障阻力作斗争.
研究的目的:
- 为MMCs制定一个改进的非单位保护计划.
- 为了提高直流电网保护中的抗故障能力.
- 确保快速可靠的故障区域识别.
主要方法:
- 分析初始故障电压逆转波 (IVRW) 特性.
- 使用触角外面积比来量化波形扭曲.
- 开发基于IVRW触角外面积比的故障识别标准.
主要成果:
- 拟议的方案表现出强大的抗故障阻力.
- 保护设置独立于模拟参数.
- 有效的断层区域识别在弱边界和高噪声下实现.
结论:
- IVRW触角外面积比为MMC直流电网保护提供了一个强大的方法.
- 这种技术通过减轻故障阻力限制,改进了传统的移动波保护.
- 拟议方案在具有挑战性的电网条件下提供可靠的保护.
相关概念视频
Line Protection with Impedance Relays
56
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
56
Radial System Protection
83
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
83
Zones of Protection
100
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
100
Power System Three-Phase Short Circuits
60
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
60
Transformers with Off-Nominal Turns Ratios
122
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
122
Maximum Power Flow and Line Loadability
86
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
86