在ADM1中包含飞灰效应:使用真实的废水校准和验证一个简单的功能
Gustavo Vargas-Morales1, Yeney Lauzurique2, Cesar Huiliñir3
1CETAQUA, Centro Tecnológico del Agua, Santiago, Chile.
Biodegradation
|May 3, 2025
概括
这项研究引入了一个新的功能,用于模拟飞灰 (FA) 对使用酒厂废水的无氧消化模型 (ADM1) 的影响. 经过验证的模型准确地预测了不同FA度的甲产量.
科学领域:
- 生物化学工程 生物化学工程
- 环境科学 环境科学
- 厌氧消化模型建模 厌氧消化模型建模
背景情况:
- 微量元素,如飞灰 (FA) 对无氧消化模型 (ADM1) 的影响仍然未得到充分探索.
- 精确的建模对于优化从工业废水中生产沼气至关重要.
研究的目的:
- 提出,校准和验证一个简单的功能,将飞灰效应纳入ADM1.
- 用真实的酒厂废水来评估模型的性能.
主要方法:
- 校准了ADM1和一个新的FA函数与来自酒厂废水的生物化学甲潜力 (BMP) 测试数据.
- 使用五种不同的FA度 (25150 mg/L) 验证了模型.
- 进行敏感性分析以确定关键参数.
主要成果:
- ADM1校准显示出很好的匹配,尽管参数值低于文献.
- 拟议的FA功能准确地模拟了抑制和刺激区域.
- 经过修改的ADM1在测试的FA水平 (NRMSE 0.06350.1342) 中预测甲产生的准确性很高.
结论:
- 开发的模型有效地将飞灰的影响整合到酒厂废水的ADM1中.
- 该模型只需要对一个参数 (ki) 进行校准,表示强度.
- 拟议的功能适用于各种飞灰度和条件.
关键词:
ADM1 ADM1 ADM1 ADM1 ADM1 ADM1 ADM1 ADM1 ADM1 ADM1 ADM2 ADM3 ADM4 ADM5 ADM6 ADM7 ADM8无氧消化消化无氧消化飞行灰的飞行灰建模建模模型是什么更多相关视频
06:26Capturing Flow-weighted Water and Suspended Particulates from Agricultural Canals During Drainage Events
Published on: November 7, 2017
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
相关概念视频
Fineness of Cement
111
The fineness of cement directly influences the rate of hydration, as the hydration begins at the surface of the cement particles. In addition to hydration, the fineness of cement is vital for various properties of concrete including workability, gypsum requirement, and long-term behavior. The fineness of cement is represented in terms of the specific surface of cement which is typically measured in square meters per kilogram, with several methods available for this determination.
Direct...
Direct...
111
Quality of Water
71
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
71
Testing Water Quality
89
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
89
Design Example: Managing Concrete Workability
63
This example deals with managing the workability of concrete for a raft foundation project under hot weather conditions. Workability is crucial for ensuring the concrete is easy to place, compact, and finish. In this scenario, a slump test — a common method to measure the workability of fresh concrete — initially indicated low workability. This was attributed to the rapid water loss from the concrete mix, exacerbated by the high temperatures causing the course aggregates to heat up.
63
