短暂的电流平衡调制,以实现双动桥式转换器的无负载阶段响应,并具有三重相位移控制

Shengzhi Zhou1, Jiahua Tang2

  • 1Department of Intelligent Manufacturing, Guangdong University of Education, Guangzhou, Guangdong, China. zhoushengzhi@gdei.edu.cn.

Scientific reports
|May 3, 2025
PubMed
概括

对于双主动桥式直流-直流转换器而言,一种新的短暂电流平衡 (TCB) 调制可最大限度地减少电感器和变压器超标电流. 这种方法确保了快速的短暂响应,没有直流偏差,提高了系统效率并减少了电磁问题.

相关概念视频

Bridge rectifier01:24

Bridge rectifier

The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
398
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
242
Half wave rectifier01:20

Half wave rectifier

A half-wave rectifier is a fundamental circuit in electronics, designed to convert alternating current (AC) voltage into a unidirectional voltage. It utilizes the simplest form of diode rectification, where the circuit comprises a single diode in series with a load resistor and an AC power source.
561
The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
488
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
130
Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
203