短暂的电流平衡调制,以实现双动桥式转换器的无负载阶段响应,并具有三重相位移控制
1Department of Intelligent Manufacturing, Guangdong University of Education, Guangzhou, Guangdong, China. zhoushengzhi@gdei.edu.cn.
Scientific reports
|May 3, 2025
概括
对于双主动桥式直流-直流转换器而言,一种新的短暂电流平衡 (TCB) 调制可最大限度地减少电感器和变压器超标电流. 这种方法确保了快速的短暂响应,没有直流偏差,提高了系统效率并减少了电磁问题.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
背景情况:
- 双活性桥 (DAB) DC-DC 转换器可能会由于不适当的直接调制而经历时间DC偏移和超越负载级电流需求.
- 这些问题导致复杂的电磁问题和系统中传导损失的增加.
研究的目的:
- 为DAB直流-直流转换器提供专用过渡电流平衡 (TCB) 调制,以实现无过渡响应.
- 为了解决和减轻三相变换 (TPS) 控制中固有的直流偏移和超越电流问题.
主要方法:
- 该研究的重点是三次相位移 (TPS) 控制,一个三维门信号方案.
- 引入了一种新的TCB调制,通过浮动参考来调整相位移,以最大限度地减少DC偏移.
- 在不同TPS稳定状态模式之间的所有过渡情况中评估TCB调制.
主要成果:
- 拟议的TCB调制实现了快速的短暂响应,而不会在TPS控制中引入直流偏移电流.
- 提出了TCB调制的统一解决方案,简化了不论稳定状态的确定.
- 理论发现通过模拟和实验测试来验证.
结论:
- TCB调制有效地将TPS控制的DAB直流-直流转换器中的直流偏移和超标电流降到最低.
- 这种方法通过减少电磁干扰和导电损失来提高系统性能.
- TCB调制提供了一个强大的和普遍适用的解决方案,用于改善DAB转换器中的短暂响应.
相关概念视频
Bridge rectifier
398
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
398
Control of Power Flow
242
There are several methods to control power flow in power systems:
242
Half wave rectifier
561
A half-wave rectifier is a fundamental circuit in electronics, designed to convert alternating current (AC) voltage into a unidirectional voltage. It utilizes the simplest form of diode rectification, where the circuit comprises a single diode in series with a load resistor and an AC power source.
561
The Delta-to-Delta Circuit
488
In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
488
Phase-lead and Phase-lag Controllers
130
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
130
Three-Phase Voltages
203
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
203