,

Da Wang1,2,3, Puyong Feng2,3, Bo Zhang2,3

  • 1State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum Beijing, Beijing 102249, China.

ACS omega
|May 5, 2025
PubMed
概括

顺序注射酸化通过创建独特的虫洞结构,增强了高温水库中酸透的深度. 与传统技术相比,这种方法使用更少的酸和更低的压力来提高效率.

相关概念视频

Titration of Polyprotic Base with a Strong Acid01:18

Titration of Polyprotic Base with a Strong Acid

The titration of a polyprotic base such as sodium carbonate with a strong acid such as hydrochloric acid results in two equivalence points on the titration curve. At the first equivalence point, the carbonate ions in the base are completely converted to bicarbonate ions. The second equivalence point corresponds to the complete conversion of bicarbonate ions to carbonic acid, which dissociates into carbon dioxide and water. The region before the first equivalence point corresponds to the...
667
Titration of a Weak Acid with a Strong Base01:30

Titration of a Weak Acid with a Strong Base

In titrating a weak acid with a strong base, different calculation methods are applied at various stages. Initially, the pH of a weak acid like acetic acid is calculated using its dissociation constant (Ka) and an ICE table. Upon addition of a strong base such as sodium hydroxide, a buffer forms, and its pH is determined using the Henderson-Hasselbalch equation. As more base is added and the titration reaches the halfway point, the pH becomes equal to the pKa of the acid, indicating equal...
1.9K
Leveling Effect01:29

Leveling Effect

In acid-base chemistry, the leveling effect refers to the limitation imposed by the solvent on the strength of acids and bases in solution. When a base stronger than the solvent's conjugate base is used, it deprotonates the solvent until the base is entirely consumed, making it ineffective against weaker acids. Conversely, an acid stronger than the solvent's conjugate acid protonates the solvent until the acid is depleted, rendering it ineffective against weaker bases. Essentially, the...
720
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
306