相关实验视频
Updated: May 9, 2025

08:44
Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
5.8K
在温度间隔20-100°C的便宜的PRT差值温度计的构造和特征
Ivo I Lozanov1, Lyudmil G Lyutov1,2
1Department of Inorganic Chemistry, Faculty of Chemistry and Pharmacy, Sofia University "St. Kliment Ohridski," Sofia, Bulgaria.
The Review of scientific instruments
|May 5, 2025
概括
使用4xPt1000 Wheatstone桥的新型无差温计提供了精确的温度差异测量. 这种具有成本效益的白金电阻温度计与传统热电偶相比,提供了更高的准确性.
科学领域:
- 计量学 计量学 计量学
- 物理 物理学 物理
- 化学 化学 化学
背景情况:
- 准确的温度差异测量在科学和工业应用中至关重要.
- 现有的方法,如热电偶,可能昂贵或含有.
- 电阻温度计 (Pt1000) 以其稳定性和准确性而闻名.
研究的目的:
- 开发和评估一个精确的,廉价的,没有的差分温度计.
- 将4xPt1000配置与2xPt1000设置的性能进行比较.
- 评估其作为热电偶的低成本替代品的适用性,用于窄边际测量.
主要方法:
- 使用4xPt1000 Wheatstone桥的差分电阻温度计的建造.
- 在实验室条件下 (20-100°C) 进行理论分析和实验测试.
- 使用2xPt1000差异温度计进行比较分析.
主要成果:
- 4xPt1000温度计显示稳定性和准确性显著提高.
- 达到0.9%以下的最大相对误差,相当于0.20°C绝对误差.
- 性能超过了一些参考热电偶 (S型) 的性能.
结论:
- 4xPt1000差分温度计是一种可行的,低成本的,无替代品,用于精确测量温度差异.
- 与不那么复杂的配置和一些热电偶相比,它提供了更高的精度和稳定性.
- 适用于需要高精度的物理,计量和化学领域的各种应用.
相关概念视频
Equipments Used to Measure Body Temperature
901
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
901
Constant Pressure Calorimetry
84.3K
Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
84.3K
Thermometers and Temperature Scales
4.9K
Any physical property that depends consistently and reproducibly on temperature can be used as the basis of a thermometer. For example, volume increases with temperature for most substances. This property is the basis for the common alcohol thermometer and the original mercury thermometers. Other properties used to measure temperature include electrical resistance, color, and the emission of infrared radiation.
As many physical properties depend on temperature, the variety of thermometers is...
As many physical properties depend on temperature, the variety of thermometers is...
4.9K
Assessing Body Temperature - Rectal
2.5K
Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
2.5K
Temperature Measurement Sites
1.4K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.4K
Assessing Body Temperature - Tympanic membrane
538
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
538