规定的时间故障估计和未知输入补偿,使用周期延迟方法
IEEE transactions on cybernetics
|May 6, 2025
概括
本研究引入了对规定的时间传感器故障估计器 (PSFE) 和线性系统中未知输入补偿的新方法. 这些技术确保了系统稳定性和在特定时间范围内对故障进行估计.
科学领域:
- 控制系统工程 控制系统工程
- 检测和诊断故障的发现和诊断.
- 线性系统分析 线性系统分析
背景情况:
- 传感器故障和未知的输入对线性控制系统构成重大挑战.
- 现有的故障估计方法往往缺乏精确的时间保证.
- 规定的时间稳定性提供了对系统趋同的增强控制.
研究的目的:
- 为线性系统设计规定的时间传感器故障估计器 (PSFE).
- 开发用于未知输入补偿的控制器,实现规定的时间稳定性.
- 解决故障估计中可区分性的局限性.
主要方法:
- 引入了一种新的过器来处理无法区分的传感器故障.
- 这个问题转化为为增强系统设计规定的时间未知输入观察器.
- 一般化的反向和周期延迟输出用于观察器和控制器设计.
- 正在开发完整和减少订单的PSFE.
主要成果:
- 设计了有效的PSFE,能够在规定的时间内估计传感器故障.
- 定期延迟控制器成功设计用于未知的输入补偿.
- 闭环系统被证明是T-规定的时间稳定 (T-PS).
结论:
- 拟议的方法为精确计时的线性系统中的故障估计和控制提供了一个强大的框架.
- 该方法有效地弥补了未知的输入,并确保了规定的时间稳定性.
- 开发的技术的有效性通过实践示例来验证.
更多相关视频
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
8.6K
07:43A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
21.5K
相关概念视频
Time-Domain Interpretation of PD Control
74
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
74
Time and frequency -Domain Interpretation of Phase-lead Control
67
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
67
Time and frequency -Domain Interpretation of PI Control
89
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
89
Linear Approximation in Time Domain
56
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
56
Load-frequency control
94
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
94
PI Controller: Design
140
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
140
