在多区商业大楼的可变空气容量终端单元中故障的数据集
Sungkyun Jung1, Yeobeom Yoon1, Piljae Im2
1Buildings and Transportation Science Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN, 37830, USA.
Scientific data
|May 9, 2025
概括
空调系统故障,如堵塞的阻尼器和空气流传感器问题,在商业建筑中浪费大量能源. 这项研究提供了一个数据集来分析故障影响,并开发更好的故障检测方法.
科学领域:
- 建筑能源系统 建筑能源系统
- 在HVAC故障检测和诊断.
背景情况:
- 空调系统的故障会降低效率和寿命,在商业建筑中浪费5%-30%的能源.
- 常见的故障包括在可变空气体积 (VAV) 系统中卡住的阻尼器和排放空气流传感器故障.
研究的目的:
- 提供高质量的,对HVAC系统故障进行良好控制的数据集.
- 为了分析故障对建筑物运行和室内条件的影响.
- 支持开发和评估故障检测和诊断 (FDD) 算法.
主要方法:
- 在一个受控的研究大楼进行了阻尼器卡住和空气流传感器故障测试.
- 在一天内生成无故障和不同故障级别的场景.
- 收集1分钟间隔数据,包括天气,建筑运行和故障状态.
主要成果:
- 该数据集捕捉了特定的HVAC故障在受控条件下的影响.
- 数据验证确保了故障和无故障场景的质量和可靠性.
- 该数据集涵盖了故障诱导和无故障的操作状态.
结论:
- 开源数据集对于了解HVAC故障影响是有价值的.
- 促进HVAC系统性能分析和FDD算法开发的研究.
- 帮助提高商业建筑的能源效率和设备寿命.
相关概念视频
Fault Types
57
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
57
Types of Building Separation Joints
172
Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
172
Heating and Cooling Curves
22.2K
When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance,...
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance,...
22.2K
Zones of Protection
102
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
102
Distribution Reliability and Automation
93
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
93
Secondary Distribution
73
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
73