评估LA-ICP-MS对具有石灰质骨的生物体进行定量成像的坚实标准:准确性,均性和激光波长效应
Ewelina Pollak-Kowa1,2, Anna Telk1, Marcin Wieczorek1
1Jagiellonian University, Faculty of Chemistry, Gronostajowa St 2, 30-387 Cracow, Poland. anna.telk@uj.edu.pl.
The Analyst
|May 9, 2025
概括
选择正确的固体标准对于准确的LA-ICP-MS分析石灰质生物来说至关重要. 这项研究评估了各种标准,提供了对海洋化物可靠元素成像的见解.
科学领域:
- 地质化学 地质化学
- 古生物学的古生物学
- 分析化学 分析化学
背景情况:
- 激光诱导分解光谱 (LA-ICP-MS) 对于化生物体的元素分析至关重要.
- 现有的固体标准 (玻璃,石颗粒) 存在矩阵匹配挑战和同质性问题.
- 石灰质骨的LA-ICP-MS研究中经常缺乏准确性验证.
研究的目的:
- 评估各种固体标准对石灰质生物的定量元素成像的有效性.
- 评估标准矩阵,激光波长和内部标准化对分析准确性的影响.
- 描述新型液体粉末标准的同质性和制备可重复性.
主要方法:
- 在珊瑚藻和藻中分析,和,使用LA-ICP-MS.
- 对比NIST 610/612玻璃标准,基于酸盐的颗粒和Cerastoderma glaucum贝粉标准.
- 研究激光波长和内部标准化对准确度的影响.
主要成果:
- 固体标准的矩阵显著影响元素定量化的准确性.
- 激光波长和内部标准化方法可以影响LA-ICP-MS结果的可靠性.
- 新的液体粉末标准证明了特征的同质性和制备的可重复性.
结论:
- 精心选择固体标准对于精确的LA-ICP-MS分析石灰质标本至关重要.
- 对于可靠的元素成像,需要矩阵匹配标准或适当的校准策略.
- 这项研究为改善海洋化物中LA-ICP-MS定量分析提供了基础.
更多相关视频
相关概念视频
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
326
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
326
Atomic Emission Spectroscopy: Lab
125
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
125
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
587
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
587