分析与石英中介发光峰相关的陷参数
S Mammadov1, M Gurbanov1, A Abishov1
1Institute of Radiation Problems, Ministry of Science and Education, Azerbaijan, 9, B. Vahabzade str, Baku, 1143, Azerbaijan.
概括
这项研究研究了石英中的热发光 (TL),揭示了超出简单的第一或第二顺序的复杂动力学. 它可以识别稳定的陷区域和不同的激活能量,这对于准确的剂量测量应用至关重要.
科学领域:
- 固态物理 固态物理
- 材料科学 材料科学 材料科学
- 地质物理学 地质物理学
背景情况:
- 石英中的热发光 (TL) 对辐射剂量敏感.
- 了解TL动力学对于准确的剂量测量至关重要.
- 石英中的中间TL峰值往往表现出复杂的行为.
研究的目的:
- 描述石中中间TL峰值的陷结构.
- 为了确定TL发光峰的动态顺序.
- 分析TL信号的热稳定性和激活能量.
主要方法:
- 同热衰变分析
- 热发光 (TL) 差异曲线的热发光 (TL) 差异曲线
- 启动能量计算初始上升方法.
主要成果:
- 石英中的TL发光峰并不严格遵循一级或二级动力学.
- 在145°C,170°C和235°C确定了三个稳定的Tm稳定区域.
- 在同热清洗过程中,随着Tstop温度的增加,明显的激活能量会减少.
结论:
- 石英TL动力学是复杂的,涉及的不仅仅是简单的捕获和重组.
- 鉴定到的稳定区域和激活能量趋势提高了对TL机制的理解.
- 这些发现提高了基于石英的热发光剂量计的准确性.
相关概念视频
Photoluminescence: Applications
340
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
340
Mass Analyzers: Common Types
523
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
523
Fluorescence and Phosphorescence: Instrumentation
484
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
484