没有重原子的超分子光敏感剂来源于传统的光体

Lingfeng Fan1, Yong Wu1, Cong-Qiao Xu2

  • 1Shenzhen Grubbs Institute, Southern University of Science and Technology, Shenzhen, 518055, China.

概括

这项研究引入了一种新的超分子方法,从常见的光体中产生无重原子光敏化剂 (PSs). 这些新的PS能有效地产生活性氧物种 (ROS),并作为酶系统的光催化剂.

相关概念视频

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.8K
Photochemical Electrocyclic Reactions: Stereochemistry01:26

Photochemical Electrocyclic Reactions: Stereochemistry

The absorption of UV–visible light by conjugated systems causes the promotion of an electron from the ground state to the excited state. Consequently, photochemical electrocyclic reactions proceed via the excited-state HOMO rather than the ground-state HOMO. Since the ground- and excited-state HOMOs have different symmetries, the stereochemical outcome of electrocyclic reactions depends on the mode of activation; i.e., thermal or photochemical.
Selection Rules: Photochemical Activation
1.8K
Cycloaddition Reactions: MO Requirements for Photochemical Activation01:12

Cycloaddition Reactions: MO Requirements for Photochemical Activation

Some cycloaddition reactions are activated by heat, while others are initiated by light. For example, a [2 + 2] cycloaddition between two ethylene molecules occurs only in the presence of light. It is photochemically allowed but thermally forbidden.
2.0K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
362
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
227
The Antenna Complex01:42

The Antenna Complex

Plants and other photosynthetic organisms comprise pigments capable of absorption of direct sunlight. These pigments are present in the reaction center - the main site of photochemical reactions as well as in the antenna complex. Under average light conditions, the rate at which reaction center pigments absorb light is far below the electron transport chain's capacity. As a result, the reaction center alone cannot provide enough energy to drive photosynthesis. The photosynthetic efficiency...
5.9K