相关实验视频
Updated: May 16, 2025

08:15
Data Communication Based on MQTT in a Polymer Extrusion Process
Published on: July 15, 2022
3.4K
在物联网供应链系统中使用的变量函数的实用安全分析和攻击策略
Narges Mokhtari1, Amirhossein Safari2, Sadegh Sadeghi3
1CPS2 Lab, Department of Communication, Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran, 16788-15811, Islamic Republic of Iran.
Scientific reports
|May 12, 2025
概括
换函数的内部结构对于超轻量级身份验证协议至关重要. 漏洞可能导致安全漏洞,如秘密披露和可追溯性攻击,即使在高效设计的系统中.
科学领域:
- 计算机科学 计算机科学
- 密码学 密码学 密码学 密码学
- 物联网 (IoT) 安全 安全 物联网
背景情况:
- 物联网 (IoT) 设备的扩散需要低成本的安全解决方案.
- 使用简单运算符 (XOR,Shift) 的超轻量级身份验证协议被探索为最小的硬件复杂性.
- 换算函数是这些轻量级协议中的关键组件.
研究的目的:
- 突出内部结构在系统安全的变换函数中的关键作用.
- 分析供应链管理ULBRAP协议的安全漏洞.
- 为已识别的函数的弱点提出解决方案.
主要方法:
- 检查了超轻量级身份验证协议中的换函数的内部结构.
- 在ULBRAP协议上进行安全分析,识别漏洞.
- 在Raspberry Pi设备上演示了攻击 (秘密披露,可追溯性).
- 量化了攻击的计算成本 (1,710,947次哈希计算,约5分钟).
主要成果:
- 调配函数中的结构弱点可能会破坏其他高效协议的安全性.
- 该ULBRAP协议容易受到秘密披露和可追溯性攻击.
- 攻击成功地证明了实际计算要求的攻击.
结论:
- 调配函数的内部设计对于强大的物联网安全至关重要.
- 排列函数中的缺陷可能导致认证协议中的重大安全漏洞.
- 解决结构上的弱点对于开发安全可靠的超轻系统至关重要.
相关概念视频
Distribution Reliability and Automation
94
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
94
Pilot and Numeric Relaying
70
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
70
Mesh Analysis
485
Mesh analysis is a valuable method for simplifying circuit analysis using mesh currents as key circuit variables. Unlike nodal analysis, which focuses on determining unknown voltages, mesh analysis applies Kirchhoff's voltage law (KVL) to find unknown currents within a circuit. This method is particularly convenient in reducing the number of simultaneous equations that need to be solved.
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
485
Properties of the z-Transform I
136
The z-transform is a fundamental tool in digital signal processing, enabling the analysis of discrete-time systems through its various properties. It is an invaluable tool for analyzing discrete-time systems, offering a range of properties that simplify complex signal manipulations. One fundamental property is linearity. For any two discrete-time signals, the z-transform of their linear combination equals the same linear combination of their individual z-transforms. This property is essential...
136
The Power Flow Problem and Solution
144
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
144
Radial System Protection
85
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
85

