通过摄影电磁显微镜研究吸烟与血压之间的相关性
Q Qananwah1, H Quran1, A Dagamseh2
1Department of Biomedical Systems and Informatics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
Biomedical engineering online
|May 12, 2025
概括
吸烟显著影响血压 (BP) 和心血管健康通过各种方法,如普通香烟,电子香烟和香烟. 像ECG和PPG这样的生理信号可以预测这些BP变化,有助于理解与吸烟有关的心血管风险.
科学领域:
- 心血管生理学心血管生理学
- 生物医学信号处理
- 医疗保健中的机器学习
背景情况:
- 吸烟是心血管疾病的主要危险因素.
- 像ECG和PPG这样的生理信号包含有关心血管状况的信息.
- 监测动态生理变化可以帮助预测吸烟相关的健康影响.
研究的目的:
- 研究不同吸烟习惯 (普通香烟,电子香烟,香烟) 对血压的影响.
- 分析不同吸烟阶段 (吸烟前,吸烟期间,吸烟后) ECG和PPG信号的变化.
- 开发一种基于吸烟习惯和阶段的机器学习模型来预测血压.
主要方法:
- 在吸烟前,吸烟期间和吸烟后的三个吸烟阶段收集了ECG和PPG信号.
- 分析心率和心电图和PPG信号的形态/统计特征.
- 开发并评估了一种机器学习模型,用于预测心压和腹压血压.
主要成果:
- 吸烟显著改变了光电脉冲图 (PPG) 的特征,包括抽缩时间,心率,高峰脉冲间隔变化和增强指数.
- 在所有吸烟习惯和阶段观察到血压变化.
- 机器学习模型准确地估计了吸烟期间和吸烟后的抽缩和放缩血压,平均误差和RMSE很低.
结论:
- 吸烟对血压和心血管系统的改变有明显的影响.
- 结合机器学习的ECG和PPG信号分析,可以有效地监测和预测吸烟引起的心血管变化.
- 这种方法提供了关于吸烟相关心血管疾病的发展的见解.
相关概念视频
Measurement of Blood Pressure
703
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
703
Sites for measruring blood pressure
1.4K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.4K
Assessment of blood pressure in brachial artery(one-step method)
549
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
549
Assessment of blood pressure in brachial artery(two-step method)
632
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
632
Pre-Procedural Guidelines for Assessing Blood Pressure
516
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
516
Equipments Used To Measure Blood Pressure
768
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
768