软,皮肤接口的无线电气测量系统用于连续监测手指和手腕关节
Hee-Sup Shin1,2, Jihye Kim3,4, Nicholas Fadell5
1Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.
Nature communications
|May 13, 2025
概括
新的可穿戴传感器为手和手腕康复提供连续的实时关节角度数据. 这种电气体测量系统在运动和日常任务期间通过精确的动力学生物反来提高治疗结果.
科学领域:
- 生物医学工程 生物医学工程
- 康复技术 康复技术 康复技术
- 可穿戴式传感器 穿戴式传感器
背景情况:
- 持续的动力生物反可以改善手和手腕康复的结果.
- 传统的关节角度测量方法是静态的,需要训练有素的治疗师.
- 在康复中需要准确,实时的关节运动跟踪.
研究的目的:
- 引入与皮肤相适应的可穿戴无线电气测量系统,用于连续测量手和手腕关节角度.
- 实现实时运动生物反,以改善治疗干预措施.
- 验证系统在模拟治疗和职业任务中的准确性,精度和实用性.
主要方法:
- 开发基于磁力计的,与皮肤一致的可穿戴无线系统.
- 使用智能设备实现基于计算机视觉的校准协议.
- 在健康的志愿者身上进行人体试验,以评估准确性和精度.
- 在模拟手术和职业任务期间测试系统.
主要成果:
- 电气计系统准确准确地捕获手和手腕关节的角度.
- 该系统通过直观的图形界面提供连续的实时动力学数据.
- 已证明适用于跟踪复杂的运动和在职业任务期间提供生物反.
结论:
- 开发的可穿戴电气测量系统为手和手腕康复中的连续动力生物反提供了可行的解决方案.
- 该系统通过提供实时运动数据来增强患者监测和治疗干预.
- 这项技术有可能改善康复结果,并预防禁忌的运动.
相关概念视频
Equipments Used to Measure Body Temperature
919
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
919
Equipments Used To Measure Blood Pressure
769
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
769
Pulse rhythm
734
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
734
Assessment of the Cardiovascular System III: Palpation
160
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
160
Assessment of blood pressure in brachial artery(one-step method)
549
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
549