对于电气钢的基本Zirka-Moroz历史依赖性歇斯底里模型的参数估计.
Martin Petrun1, Ermin Rahmanović1
1Institute of Electrical Power Engineering, Faculty of Electrical Engineering and Computer Science, University of Maribor, 2000 Maribor, Slovenia.
Materials (Basel, Switzerland)
|May 14, 2025
概括
这项研究简化了Zirka-Moroz历史依赖性歇斯底里模型的参数估计. 它分析了电气钢的过程,对于精确的磁性元件建模至关重要.
科学领域:
- 材料科学 材料科学 材料科学
- 电气工程 电气工程
- 计算物理 计算物理
背景情况:
- 历史依赖的hysteresis模型对于磁性元件的精确磁化和功率损耗计算至关重要.
- 扭曲的激发波形产生复杂的磁化模式,需要先进的建模技术.
- 齐卡-莫罗兹模型平衡了准确性和复杂性,但提出了参数估计的挑战.
研究的目的:
- 为Zirka-Moroz历史依赖性歇斯底里模型的参数估计程序提供见解.
- 分析模型的性能和参数估计,用于不同类型的电气钢.
- 了解模型在特定应用中的功能,挑战和局限性.
主要方法:
- 使用一个基本的两步参数估计程序.
- 雇员测量了第一阶段反转曲线 (FORCs) 用于分析.
- 评估了两个非面向和一个面向粒度的电气钢样本.
主要成果:
- 估计每个电气钢样本的两个参数集.
- 将估计的参数与非定向电气钢的参考值进行比较.
- 证明了估计程序在不同钢材类型中的适用性.
结论:
- 对于Zirka-Moroz模型来说,使用各种电气钢的参数估计程序是可行的.
- 该分析强调了在实际磁性元件设计中实施该模型的关键方面.
- 进一步了解特定钢材类型的模型限制和要求.
相关概念视频
Temperature Dependent Deformation
131
In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
131
Thermal expansion and Thermal stress: Problem Solving
1.1K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.1K
Multimachine Stability
111
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
111
Parametric Survival Analysis: Weibull and Exponential Methods
290
Parametric survival analysis models survival data by assuming a specific probability distribution for the time until an event occurs. The Weibull and exponential distributions are two of the most commonly used methods in this context, due to their versatility and relatively straightforward application.
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...
290
Routh-Hurwitz Criterion I
113
Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
113
Transformers with Off-Nominal Turns Ratios
122
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
122