适应性模糊PI控制的动态电压恢复器,用于减轻电压下降
Nirmalya Mallick1, Chandan Kumar Shiva2, Sachidananda Sen2
1Electrical Engineering Department, Sanaka Educational Trust's Group of Institutions, Durgapur, India.
Scientific reports
|May 14, 2025
概括
本研究介绍了一种带有混合储能系统的动态电压恢复器 (DVR),以提高电源质量. 优化的DVR有效地减轻了电压下降,确保了敏感负载的稳定功率.
科学领域:
- 电气工程 电气工程
- 电力系统工程 电力系统工程
背景情况:
- 敏感负载需要稳定的电压才能可靠运行.
- 电机启动时的电压下降和故障会破坏电源质量.
研究的目的:
- 推出一个高性能动态电压恢复器 (DVR).
- 为了减轻分布网络中的电压下降和相位中断.
主要方法:
- 使用混合直流储能系统 (超级电容器和PEMFC).
- 实现了一个具有智能能源管理的多输入单增压转换器.
- 采用模糊增益计划PI控制器用于自适应电压恢复.
主要成果:
- 在电压配置恢复方面取得显著改进.
- 在没有过度调制的情况下实现了持续的系统稳定性.
- 有效地降低掉落指数,最大限度地减少电压掉落的严重性.
结论:
- 拟议的DVR为电力质量挑战提供了可扩展和有弹性的解决方案.
- 混合储能系统可确保在各种电压下降期间提供可靠的支持.
- 在实验性低压设置上验证的有效性.
更多相关视频
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
160
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.5K
相关概念视频
Voltage Doubler Circuit
427
A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
427
Time-Domain Interpretation of PD Control
75
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
75
PI Controller: Design
157
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
157
Power Factor Correction
147
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
147
Time and frequency -Domain Interpretation of PI Control
93
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
93
Bridge rectifier
415
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
415